Mechanical wire type:
1.Stopping the engine.
2.Setting the gearshift at F or R.
3.Turning the engine switch ON. The
buzzer will sound once.
4.Putting in and pull out the
emergency stop switch clip 5 times
within 20 seconds.
The buzzer will sound once when
the hour counter is reset.
Periodic maintenance is required
when either the operating hours or the
time since last maintenance reaches
the prescribed limit. Therefore, peri-
odic maintenance may be required
based on the number of months since
the last maintenance before the alert
based on engine operating hours dis-
plays (see Maintenance Schedule on
page 114).
Reset the hour counter whenever
maintenance is performed, whether
based on the time interval or the
number of operating hours.
<Operating hour notification timing>
20
80 hours
hours
after reset
Start of
Notify
operation
<Display>
Steps
Outboard
motor
Display
Switch ON
Not shown
Maintenance
Maintenance
indication on
indication
display
https://www.boat-manuals.com/
CONTROLS AND FEATURES
Every 100 hours
100 hours
after reset
Notify
1
2
Engine switch ON
Shown
Maintenance
indication
Notify
3
4
Start engine
Gear at F or R
Shown
Not shown
Maintenance
Maintenance
indication
indication