Installing the software
NN43041-465
Standard 01.04
Note: For a new install, the FMD must be partitioned (followed by a
reboot).
Procedure 9 outlines the steps required to upgrade the CPPM BIOS to
Version 15 for Call Server applications.
Procedure 9
Upgrading the CP PM BIOS to Version 15
1
Using a bootable Call Server RMD, create a directory titled bios in the
RMD root directory.
2
Place the LMDU74AA_0015.ROM file in bios directory on your RMD.
3
Connect to Serial Port 0 of the CPPM.
4
Insert the RMD in the faceplate compact flash location, reset CP-PM and
select faceplate boot option.
5
At the Main Menu, select <t> - To Tools Menu.
6
From the Tools Menu, select <t> - To replace CPU board BIOS.
7
Confirm the file name and bios upgrade. The flash then erases/
reprograms and returns to the tools menu.
Note: Do not interrupt the flash upgrade process.
8
Click the RST button.
9
The card reboots and the upgrade is now complete.The BIOS Version is
updated to NTDU74AA 15.
Changes included in Version 15:
1
Pressing F to force the card to boot off the faceplate drive will immediately
cause the card to attempt to boot instead of delaying until all '.' have
printed.
Changes included in Version 14:
1
The CMOS configuration option to configure the CP-PM slot has been
removed to avoid confusion.
Changes included in Version 13:
1
Screen corruption during BIOS display has been cleaned up.
2
Manufacturing tests have been completed and are included in FBUG.