The NTDW66AAE5 model of the Nortel CP PM server is designed for use in
a CS 1000M system. The first task that must be performed is to install the hard
drive shipped with the server. For instructions, see "Install the hard drive on
a Nortel CP PM Signaling Server" in Signaling Server: Installation and
Commissioning (NN43001-312).
You can insert the NTDW66AAE5 model into any slot of a CS 1000M
Universal Equipment Module (UEM) except slot 7. The External Peripheral
Equipment Controller (XPEC) is next to slot 7 and prevents the double wide
faceplate of the NTDW66AAE5 model from seating into slot 7.
The next task that you must perform is to install ELAN and TLAN Ethernet
ports on the back of the CS 1000M UEM. These ports are used to connect
your Nortel CP PM Signaling Server to the ELAN and TLAN Ethernet
subnets of your CS 1000M system.
Use the following procedure to install ELAN and TLAN Ethernet ports on the
back of a CS 1000M UEM.
Communication Server 1000E Upgrade
Installing ELAN and TLAN Ethernet ports on the back of a CS 1000M
Universal Equipment Module (UEM) is service-disrupting. Power to the
shelf must be turned off during this procedure.
Installing a Signaling Server
IMPORTANT!
Option 11C Chassis to Communication Server 1000E