Nortel 1000E Upgrade page 110

Option 11c chassis upgrade
Table of Contents

Advertisement

Page 110 of 228
Configuring the MGC
NN43041-465
Standard 01.04
Installing the software
Use Procedure 12 to configure the MGC through CLI.
Procedure 12
Configuring the MGC through CLI
Note: Initial configuration of the MGC is command line ONLY.
The MGC is shipped with "gold" software in onboard flash memory. If
centralized software upgrade is enabled on the Call Server, the MGC is
upgraded automatically (or it can be upgraded manually through LD 143). If no
IP information exists on the MGC, it will boot directly into the setup menu.
The MGC Shells can be accessed using the following commands:
<CTRL>+OAM, (provide OAM username and password to access
OAM shell)
<CTRL>+LDB, (provide LDB username and password to access
LDB)
Note: The default password is admin1 and 0000. Once this card has
synchronized with the call server, this password changes to the call server
default password.
1
Enter network IP information at the MGC setup menu:
ELAN IP : 192.168.3.33
ELAN subnet mask : 255.255.255.0
ELAN gateway IP : 192.168.3.1
Primary CS IP : 192.168.3.32
Note: Depending on the date of manufacture, the Gold image may
prompt for TLAN and/or secondary call server information. If these
prompts appear they can be ignored. This information is configured
through EM and is retrieved by the MGC at registration. The new image
after upgrade will not have these prompts.
2
Enter port and security parameters, if required:
Note: This step is only necessary if you are using advanced security
features.
Change MGC advanced parameters? (y/[n]) : y
TLAN is set to auto negotiate, change? (y/[n]) : y
July 2007