Specifications; Chassis Physical Design - Dell EMC PowerSwitch N2200-ON Series Installation Manual

Table of Contents

Advertisement

This section lists the N2200-ON Series switch specifications.
CAUTION:
Operate the product at an ambient temperature not higher than 45°C (113°F).
NOTE:
For RoHS information, see
Topics:

Chassis physical design

IEEE standards
Agency compliance
Chassis physical design
Table 10. Chassis physical design
Parameter
Height x Width x Depth measurements, excluding the PSU and fan
tray handle
Chassis weight with one PSU installed
Rack clearance required
Table 11. Environmental parameters
Parameter
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Maximum thermal output without PoE
Maximum operational altitude
54

Specifications

Restricted Material
Compliance.
Specifications
(PSU and fan tray handle adds 1.18 in or 30 mm)
Front: 5 inches (12.7 cm)
Back: 5 inches (12.7 cm)
Specifications
0° to 45°C (32°F to 113°F) continuously
5% to 95% (RH), non-condensing
–40° to 70°C (–40° to 158°F )
5% to 95%, non-condensing
10,000 feet (3,048 meters)
Specifications
1.71 in x 17 in x 15.75 in (H x W x D)
43.5 mm x 434 mm x 400 mm (H x W x D)
N2224X-ON: 14.30 lbs (6.485 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
N2224PX-ON: 14.70 lbs (6.67 kg)—PSU is 1.95 lbs, 0.88 kg
(1050W)
N2248X-ON: 15.09 lbs (6.845 kg)—PSU is 1.75 lbs, 0.79 kg
(550W)
N2248PX-ON: 15.77 lbs (7.155 kg)—PSU is 2.0 lbs, 0.90 kg
(1600W)
NOTE:
Reduce maximum temperature by 1°C/125
meters (1°F/228 feet) above 950 meters (3,117 feet).
N2224X-ON: 105 W = 811.58 BTU/hr
N2224PX-ON: 115 W = 811.58 BTU/hr
N2248X-ON: 160 W = 1111.66 BTU/hr
N2248PX-ON: 170 W = 1111.66 BTU/hr