Absolute encoders

Advertisement

4.8 Node number: DIP A
WARNING
Power supply must be turned off before performing this operation!
The node number must be set via hardware using DIP A dip-
switches.
Allowed addresses are from 0 to 125. The default value is 1.
DIP A:
Turn the power supply off and set the node number in binary value;
consider that: ON=1, OFF=0
bit
1
LSB
0
2
Example
Set node number = 25:
25
= 0001 1001