Datalogic AMT58-PB Series Instruction Manual page 24

Absolute encoders

Advertisement

AMT58x-PB Profibus®
Class 2 example
In the Parameter Assignment page, some items (Code sequence,
Class 2 functionality, Scaling function) are to be set by scrolling
through the available options in the drop-down box. While the
parameters concerning the resolution must be entered in decimal
notation. Please note that the Total resolution value has to be split
into two separate fields, namely Total resolution (high) and Total
resolution (low). This value in fact must be entered in two words.
Please refer to the following examples to understand how the Total
resolution value has to be divided into two parts: a high part and a
low part.
WARNING
You can set new values next to the Counts per revolution and Total
resolution items only if Class 2 functionality = ENABLED; if Scaling
function = ENABLED the set resolution values are enabled and used
by the encoder; on the contrary, if Scaling function = DISABLED you
are allowed to set new resolution values, however they are not
enabled even if sent to the encoder: the encoder still goes on using
the default values uploaded from the GSD file, NOT the new entered
values, until you enable the Scaling function.