4.
Electrical connections
4.1 Connection cap
WARNING
Do not remove or mount the connection cap with power supply
switched ON. Damage may be caused to internal components.
The terminal connectors for connecting the power supply and the
BUS IN and BUS OUT cables (BC-PB connection cap) as well as the
dip-switches meant to set the node ID and activate the termination
resistance are located inside the encoder connection cap. Thus you
must remove the connection cap to access any of them.
NOTE
Be careful not to damage the internal components when you perform
this operation.
To remove the connection cap loosen the two screws 1. Please be
careful with the internal connector.
Always replace the connection cap at the end of the operation. Take
care in re-connecting the internal connector. Tighten the screws 1
using a tightening torque of approx. 2.5 Nm.
WARNING
You are required to check that the encoder body and the connection
cap are at the same potential before replacing the connection cap!