Operate in API mode

Remote AT Command Request frame - 0x17

Description
Used to query or set device parameters on a remote device. For parameter changes on the remote
device to take effect, you must apply changes, either by setting the Apply Changes options bit, or by
sending an AC command to the remote.
Format
The following table provides the contents of the frame. For details on frame structure, see
format.
Frame data
fields
Frame type
Frame ID
64-bit
destination
address
Reserved
Remote
command
options
AT command
Command
parameter
Example
The following example sends a remote command to:
In this example, the 64-bit address of the remote device is 0x0013A200 40401122.
Frame data fields
Start delimiter
Length
Frame type
Frame ID
XBee® SX 868 RF Module User Guide
Offset Description
3
0x17
Identifies the UART data frame for the host to correlate with a subsequent
4
ACK. If set to 0, the device does not send a response.
MSB first, LSB last. Set to the 64-bit address of the destination device.
5-12
13-14
0x02 = Apply changes on remote. If you do not set this, you must send an
15
AC command on the remote device for changes to take effect.
Set all other bits to 0.
Command name: two ASCII characters that identify the command.
16-17
18-n
If present, indicates the parameter value you request for a given register.
If no characters are present, it queries the register.
Offset
Example
0
0x7E
MSB 1
0x00
LSB 2
0x10
3
0x17
4
0x01