Diagnostics
5.2 Diagnostics using LEDs
5.2.2.2
Active Line Module booksize
Table 5- 5
Meaning of the LEDs on the Active Line Module
State
Ready
DC link
Off
Off
Green
Off
Orange
Red
Orange
Orange
Red
–
Green / red
–
flashing light
0.5 Hz
Green / red
–
flashing light
2 Hz
Green /
–
orange
or
Red / orange
5.2.2.3
Basic Line Module booksize
Table 5- 6
Meaning of the LEDs on the Basic Line Module
State
Ready
DC link
Off
Off
Green
Off
Orange
Red
244
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The DC link voltage is present.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The DC link voltage is too high.
DRIVE-CLiQ communication is being established.
At least one fault is present in this component.
Note:
LED is controlled irrespective of the corresponding messages
being reconfigured.
Firmware is being downloaded.
Firmware download is complete. Wait for POWER ON.
Component detection via LED is activated (p0124).
Note:
Both options depend on the LED status when module recog-
nition is activated via p0124 = 1.
Description, cause
Electronic power supply is missing or outside permissible
tolerance range.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The DC link voltage is present.
The component is ready for operation and cyclic DRIVE-CLiQ
communication is taking place.
The DC link voltage is too high.
Remedy
–
–
–
Check the line voltage
–
Remedy and acknowledge
fault
–
Carry out a POWER ON
–
Remedy
–
–
–
Check the line voltage.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0