Default password settings
● "SINAMICS" user: No password set.
For these users we recommend that a password is assigned. The password must
comprise at least 8 characters.
With a password, you prevent an attacker from assigning a password and thereby
blocking other commissioning engineers.
● "Administrator" user: No password set.
A password must be assigned for this user. The password must comprise at least 8
characters. If no password has been assigned, the following warning appears when
attempting to log on "A09000: Web server security: Administrator password not set".
Note
Secure passwords
The password must include the following elements to provide protection against
unauthorized access, e.g. unauthorized persons.
• At least 8 characters
• Uppercase and lowercase letters
• Numbers and special characters (e.g. ?!%+)
The password must not be used elsewhere.
Enabling the user "SINAMICS" and/or "Administrator"
The "SINAMICS" user and the "Administrator" user can be enabled with their own specific
rights. You can also set whether password protection will be active for the "SINAMICS" user.
To enable a user and activate a password, proceed as follows:
1. Activate the "Enable SINAMICS user" option.
AND / OR
2. Activate the "Enable administrator user" option.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
4.8 Basic parameterization of the drive objects
Commissioning