Result of the controller optimization. Comparison of the values before and after tuning.
Dynamic response settings via defined stages or via a dynamic response factor
Activate/deactivate master control.
Activates an infeed unit.
Configuration / distance limit
Activates the measurement for controller optimization.
Switch on/switch off controller optimization.
Advanced settings for selected parameters
Status of controller optimization
Figure 4-70
"One Button Tuning" input screen for S120
4.10.4.2

Performing One Button Tuning

The "One Button Tuning" function is an important component of basic commissioning. Using
this function, the mechanical drive train is measured using short test signals. Using this
measurement, the function optimally adapts the controller parameters to the mechanical
system being used. Further, this function allows you to determine optimum controller settings
with just a few entries.
Restrictions
Only the motor measuring system is used to optimize the position controller. On the other
hand, using an external measuring system can result in an unstable controller setting.
Commissioning with Startdrive
Commissioning Manual, 12/2018, 6SL3097-5AA10-0BP0
Commissioning
4.10 Commissioning a drive