7. Basic Operation

7.1. Turning the Scale ON/OFF and Weighing

Step 1
Ground the scale using the earth terminal.
Step 2
Confirm that nothing is placed on the weighing pan.
Step 3
Confirm that local voltage and receptacle type are correct before connecting the scale.
Step 4
The scale is turned on or off using the ON/OFF key.
Step 5
Check the accuracy of weighing.
Allow a 30-minute warm up period before calibration
Step 6
With nothing on the weighing pan, press the ZERO key to display the zero value.
Step 7
Gently place an article to be weighed on the weighing pan.
Step 8
Wait for the stability indicator to be displayed, then read the weighing value.
Step 9
Gently remove the article from the weighing pan.
Step 10 Turn off the display using the ON/OFF key.
Note
When the display is turned off by pressing the ON/OFF key, the power is still being supplied
inside the circuit of the scale. To shut off the power completely, disconnect the power cord of
the scale from the receptacle.
Please confirm that the local voltage and the receptacle type are correct for your scale.

7.2. Power on Zero Function and Power on Tare Function

Power on Zero Function:
When nothing is placed on the weighing pan and the scale is turned on using the ON/OFF key, the
weighing value is assumed as the reference value of weighing. The zero value as gross value and
zero point indicator are displayed. The power on zero function can be used when the weighing value
is within the threshold value
Earth Terminal
Main Power Cord
from the zero point at calibration.
Stability Indicator
Zero Point Indicator
ON/OFF Key
Power Terminal
15
ZERO Key