USC LPX Operator's Manual page 70

Automated seed treater
Hide thumbs Also See for LPX:
Table of Contents

Advertisement

1. Remove and clean the atomizer housing.
2. Remove the atomizer head and
stainless steel plumbing. The
atomizer head can be disassembled
(right), for easier cleaning. It is
threaded together and can simply be
unscrewed.
3. Reinstall the atomizer head and
plumbing. Grease the bearing and
spin the atomizer head a few times
to ensure all grease has been
worked into the bearings.
1. Make certain the inside of the tank is completely drained of chemical residue and
thoroughly flush the inside of the tank with clean water.
2. Remove and clean the filter.
3. Pump clean water through all areas of the plumbing including the mix tank, flow
meter, and valves. It may be necessary to move the position of the air actuated
3-way valve from recirc to process in order to clean the chemical lines that run to
the seed treater.
4. Open all drain points, valves, and filter to let as
much of the liquid drain as possible.
5. If the seed treater will be exposed to possible
freezing temperatures, the final flush of the
system should be made with an non freezable
liquid. Or use compressed air to blow the lines
out from any moisture.
6. Release pump heads (right) and remove tubing
to prevent any unnecessary wear.
Page 70
LPX AUTOMATED SEED TREATER
ATOMIZER CHAMBER
LIQUID SYSTEM
USC,
LLC
Pump Head Open