USC LPV Operator's Manual

USC LPV Operator's Manual

Portable seed treater
Hide thumbs Also See for LPV:

Advertisement

Quick Links

LPV PORTABLE SEED TREATER
Operators Manual
Document: TD-09-06-1052
Revision: A
2320 124th Road
Sabetha, Kansas 66534
PH: (785) 431-7900
FAX: (785) 431-7950
www.uscllc.com
Revision Effective 28 MAR 2018

Advertisement

Table of Contents
loading

Summary of Contents for USC LPV

  • Page 1 LPV PORTABLE SEED TREATER Operators Manual Document: TD-09-06-1052 Revision: A 2320 124th Road Sabetha, Kansas 66534 PH: (785) 431-7900 FAX: (785) 431-7950 www.uscllc.com Revision Effective 28 MAR 2018...
  • Page 2 OVERVIEW The purpose of this manual is to provide you with the basic information needed to operate and maintain the LPV Portable Treater It does not hold USC, LLC liable for any accidents or injuries that may occur. The technical information provided in this document is based on extensive testing under controlled conditions at the USC research and development facility.
  • Page 3 If there is any damage or shortages, the purchaser must immediately notify USC, LLC. Ownership passes to purchaser when the unit leaves the USC, LLC. premises. The purchaser is responsible for unloading and mounting all components of the equipment.
  • Page 4 PORTABLE LPV TREATER Document the vehicle identification number for future reference. On gooseneck trailers, the V.I.N. is located on a sticker on the side near the top of the gooseneck as shown below. V.I.N. Number TRAILER V.I.N. NUMBER:_______________________________________________ Document the vehicle identification number for future reference. On bumper hitch trailers, the V.I.N.
  • Page 5: Table Of Contents

    PORTABLE LPV TREATER Table of Contents Section Contents Page # Section A Safety Instructions ..............6 Section B Installation ................15 Section C Mechanical Operation .............. 17 Fill Hopper, Inlet Conveyor ............. 18 Outlet Conveyor Hydraulics ............. 18 Outlet Conveyor ..............18 Portable Treater Overview ............
  • Page 6: Section A

    Provides additional information that the operator needs to be INSTRUCTIONS aware of to avoid a potentially hazardous situation. The minimum clearance height requirement for the LPV Portable Treater is the same as a standard semi trailer, 13 FEET 6 INCHES.
  • Page 7 PORTABLE LPV TREATER Mandatory Lockout Power Symbol. Disconnect, lockout and tagout electrical and other energy sources before inspecting, cleaning or performing maintenance on this panel. International Safety Alert Symbol. The exclamation point (!) surrounded by a yellow triangle indicates that an injury hazard exists.
  • Page 8 EMERGENCY STOP There are three Emergency Stop push buttons on the Portable LPV Seed Treater. One is located on the I / O control panel mounted on the side of the treater, and one each on the Treater Control and Main Control Panels mounted on the side of the trailer.
  • Page 9 PORTABLE LPV TREATER YOU are responsible for the SAFE operation and maintenance of your USC, LLC equipment . YOU must ensure that you and anyone else who is going to operate, maintain or work around the equipment be familiar with the operating and maintenance procedures and related SAFETY information contained in this manual.
  • Page 10 PORTABLE LPV TREATER 4. Provide a fire extinguisher for use in case of an accident. Store in a highly visible place. 5. Do not allow children, spectators or bystanders within hazard area of machine. 6. Wear appropriate protective gear. This includes but is not limited ...
  • Page 11 3. Stay away from overhead power lines when moving equipment. Electrocution can occur without direct contact. 4. Operate the equipment on level ground free of debris. USC strongly recommends that the trailers is attached to the tow vehicle whenever the discharge conveyor is deployed and the treating system is in use.
  • Page 12 2. Replace safety labels that are missing or have become illegible. 3. Replaced parts that displayed a safety label should also display the current label. 4. Replacement safety labels are available. Contact USC at (785) 431-7900 . How to Install Safety Labels: ...
  • Page 13 Think SAFETY! Work SAFELY! REMEMBER—If safety labels have been damaged, removed, become illegible, or parts replaced without safety labels, new labels must be applied. New safety labels are available from USC at (785) 431-7900. Part # 09-02-0010 Part # 09-02-0003...
  • Page 14 PORTABLE LPV TREATER Part # 09-02-0007 Part # 09-02-0006 Part # 09-02-0011 Part # 09-02-0009 Part # 09-02-0012 Page 14...
  • Page 15: Section B

    The treater panel is the only equipment that is hard wired (below). This will power the USC LPV Seed treater and any attached conveyors. All other equipment requires a properly grounded 110V source.
  • Page 16 4. If not using a generator, disconnect power before moving the treater to another location. When using a generator as a power source, USC recommends grounding the treating system according to local electrical codes. Two ground lugs are provided on the trailer. One at the left front corner and one on the right rear corner of the trailer.
  • Page 17: Section C

    PORTABLE LPV TREATER Section Mechanical Operation The Tube Series Conveyor is designed to efficiently move seed between a storage facility or seed totes and a truck, trailer or seed treater. Power is provided by an electric motor. Be familiar with the machine before starting.
  • Page 18: Fill Hopper, Inlet Conveyor

    PORTABLE LPV TREATER PORTABLE LPV TREATER OVERVIEW FILL HOPPER The fill hopper holds 65 units of seed. The hopper feeds into the inlet conveyor using a rack and pinion gate. INLET CONVEYOR The 17 foot inlet conveyor feeds into the seed treater supply hopper. The conveyor plugs into a receptacle on the bottom of the treater control panel marked (Inlet Conveyor).
  • Page 19: Portable Treater Overview

    PORTABLE LPV TREATER PORTABLE LPV TREATER OVERVIEW Page 19...
  • Page 20 PORTABLE LPV TREATER PORTABLE LPV TREATER OVERVIEW Page 20...
  • Page 21: Section D

    115V outlet.  The LPV Treater Control Panel is an enclosure that contains the electrical components required to actuate the seed treater. This includes the VFDs for the seed wheel and atomizer. Power for the treater is supplied here.
  • Page 22: Treater Setup

    The following steps outline the set-up of your USC Portable LPV Treater : 1. Clear the area of bystanders, especially small children, before moving.
  • Page 23 8. If using a fixed power source, provide power using the instructions on page 15. If using the USC provided generator, follow steps one through four to operate the generator. Before you start the generator, ensure that all switches on the treater, pumps stands, hydraulic motor and control panels as well as the main disconnect switch on the generator are in the OFF position.
  • Page 24 PORTABLE LPV TREATER GENERATOR OPERATION 8. (Continued). STEP 2: Start Generator. Press the green Start button on the generator. There will be a short pause for system checks, then generator will begin cranking over to start. Once the generator is running,...
  • Page 25 PORTABLE LPV TREATER TREATER SET UP 9. Now that the generator is up and running, Turn on the power to the treater, treater I / O and Main Control Panels. 10. Use the following steps to deploy the discharge conveyor.
  • Page 26 PORTABLE LPV TREATER TREATER SET UP STEP 4: Press the black start button on the hydraulic motor power switch. STEP 5: Use the left control lever to raise the outlet conveyor until it is out of the cradle. STEP 6: Use the right control lever to rotate the outlet conveyor out until it reaches the dead stop, a full 90 degrees from the trailer.
  • Page 27: Preparing Treater For Transport

    PORTABLE LPV TREATER PREPARING TREATER FOR TRANSPORT 1. Run the system untill all of the seed is out of the treater and the outlet conveyor. 2. Go to the main control panel HMI treater main screen. Press the HOA button.
  • Page 28: Section E

    PORTABLE LPV TREATER Section Troubleshooting TROUBLESHOOTING Below is a table describing the most frequent problems and solutions with the Inlet and Outlet conveyors. For further assistance, contact the USC Service department at (785) 431-7900. Problem Possible Cause Solution Conveyor will not run.
  • Page 29: Unplugging

    PORTABLE LPV TREATER UNPLUGGING In unusual moisture or material conditions, the machine can plug. When unplugging, follow this procedure: 1. Place all controls in neutral or off, stop motor, disable and lock out power source before unplugging. 2. Remove the nut, bolt and sliding clean out door from the bottom of the inlet tube section of the conveyor.
  • Page 30: Section F

    Section Maintenance Proper maintenance of the Portable LPV Treater is critical for peak performance, reliability and accuracy of this system. The following is a guideline for the type of maintenance and servicing that should be performed on this unit. Your environment and uses may require additional maintenance and service beyond this list to assure a reliable and safe unit.
  • Page 31 PORTABLE LPV TREATER CONVEYOR SERVICING INTERVALS Every 40 hours or Weekly 1. Check the conveyor belt tension and alignment. 2. Grease conveyor bearings. A. Two bolt flanged bearings, tail roller bearings right and left (2 locations). B. Two bolt flanged bearings, drive roller bearings right and left (2 locations).
  • Page 32 PORTABLE LPV TREATER CONVEYING BELT TENSION AND ALIGNMENT-TAIL END A contoured belt with molded flights is used to convey material along the frame. The tension and alignment of the belt should be checked weekly, or more often if required, to be sure that it does not slip or run to one side. A properly tensioned belt will not slip when it is operating.
  • Page 33 PORTABLE LPV TREATER CONVEYING BELT ALIGNMENT - HEAD END 1. A misaligned belt will track toward the loose side. Set the tracking by loosening the bearing mounts on the tight side and using the bearing position bolt to move the end of the head roller toward the tail.
  • Page 34 PORTABLE LPV TREATER DRIVE BELT TENSION & ALIGNMENT Power to the conveying belt is transmitted through a V-belt. The V-belt drive system must be maintained at the proper belt tension and pulley alignment to obtain the desired performance and life. When maintaining the belt drive system for the electric...
  • Page 35: Section G

    PORTABLE LPV TREATER Section Belt Tensioning Specification V-Belt tensioning adjustment can be made using a tension meter or other type spring scale using the following procedure. After seating the belts in the groove and adjusting center distance so as to take up the slack in the belts, further increase the tension until only a slight bow on the slack side is apparent while the drive is operating under load.
  • Page 36: Section H

    Section Storage When storing the Portable LPV Treater for long periods of time, the following procedure must be followed to reduce the chance of rust, corrosion and fatigue of the conveyor. You can also use these steps when storing the machine for the winter.
  • Page 37 PORTABLE LPV TREATER NOTES: Page 37...
  • Page 38: Section I

    PORTABLE LPV TREATER Section Mechanical Drawings MANUAL TUBE ASSEMBLY (13-05-0322) Item # Part # Description 06-01-0010 BOLT .313-18 X 0.75 ZP GR5 06-03-0019 NUT, FLG .3125-18 UNC ZP GRADE 5 06-05-0011 WASHER, .3125 FLAT 18-8 SS 08-07-0050 HOLDER MANUAL 3.25 DIA...
  • Page 39 PORTABLE LPV TREATER ELECTRIC POWER PACK SWITCH ASSEMBLY (03-13-0037) Item # Part # Description 03-04-0136 MP MNL 24-32A 600V TMQ GV2ME32 03-08-0300 CONN CG .75NPT .450-.709 3235LTF 03-08-0309 NUT NYLOC .750 NPT 8466 05-10-2002 BRKT SW MP ENCL 06-03-0017 NUT,LOCK, #8-32 ZP NYLON INSERT 06-06-0012 SCRW MACH 8-32 X .750 PHLP RDHD ZP...
  • Page 40 PORTABLE LPV TREATER ELECTRIC POWER PACK ASSEMBLY (13-08-0721) Page 40...
  • Page 41 PORTABLE LPV TREATER ELECTRIC POWER PACK ASSEMBLY (13-08-0721) Item # Part # Description 01-01-0257 HYD PWR PK 2HP 1.0GPM 3000PSI 02-02-0125 VLV HYD 2 SPOOL 8GPM 02-05-0069 FTTG HYD STGHT 8MJ-8MOR 02-05-0074 FTTG HYD STGHT 8MJ-6MP 02-06-0059 FTTG HYD 90 DEG 8MJ-8FJX...
  • Page 42 PORTABLE LPV TREATER 5 HP MOTOR DIRECT DRIVE ASSEMBLY (13-05-0653) Page 42...
  • Page 43 PORTABLE LPV TREATER 5 HP MOTOR DIRECT DRIVE ASSEMBLY (13-05-0653) Item # Part # Description 01-02-0060 BUSH 1.000IN BORE TYPE H 01-08-0120 SHEAVE 2BK190H 01-08-0121 BELT BX88 01-08-0122 SHV 2BK36 X 1.125 FHSH BORE 05-06-0127 CVR BELT DRV 06-01-0006 BOLT, .250-20 X .75 UNC ZP GRADE 5 06-01-0138 BOLT, FLG .3125-18 UNC ZP GRADE 5;...
  • Page 44 PORTABLE LPV TREATER REV ECN INITIAL DR LPV TREATER CONTAINMENT PAN ASSEMBLY (13-05-0609) Item # Item # Part # Description 02-06-0012 FTTG 90 DEG .500NPT FM SS FILENAME: 13-05-0609 = LPV Contain Pan THIS MATERIAL IS THE TOLERANCES U S C, CONFIDENTIAL AND L L C.
  • Page 45 FTTG .750 NPT DBL THD PPE BULKHEAD U S C, CONFIDENTIAL AND L L C. FRACTIONS: +/- 1/8" TITLE: ASSY PORT CONTAIN PAN LPV 2PMP SHEET 1 OF 1 PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE...
  • Page 46 TOLERANCES U S C, CONFIDENTIAL AND L L C. FRACTIONS: +/- 1/8" TITLE: ASSY FOLD PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE Sabetha, Kansas 66534 USA USED WITHOUT PERMISSION. ANGLES: +/- 1°...
  • Page 47 PORTABLE LPV TREATER FOLD UP STEP ASSEMBLY (13-05-0592) Item # Part # Description 06-01-0069 BOLT .500-13 X 1.00 ZP GR5 06-01-0124 BOLT FLG .375-16 X .750 ZP GR5 06-03-0004 NUT NYL LOCK .500-13 ZP GR5 06-03-0014 NUT LOCK FLG .375-16 ZP GR5 06-05-0005 WSHR FLAT .500 ZP...
  • Page 48 U S C, CONFIDENTIAL AND L L C. FRACTIONS: +/- 1/8" TITLE: ASSY EXT HOPP PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE Sabetha, Kansas 66534 USA USED WITHOUT PERMISSION. ANGLES: +/- 1°...
  • Page 49 PORTABLE LPV TREATER TREATER INLET HOPPER EXTENSION ASSEMBLY (10550E) DETAIL B DETAIL C Item # Part # Description 03-08-0130 PLUG STEEL 22MM 05-04-0016 WDMT FRONT PIVOT ROD 05-10-4064 PLT HOPP 6IN EXT VIEW 06-01-0006 BOLT, .250-20 X .75 UNC ZP GRADE 5 06-01-0062 BOLT CRG .500-13 X 1.25 ZP GR5...
  • Page 50 PORTABLE LPV TREATER OUTLET CONVEYOR REST ASSEMBLY (13-05-0622) Item N Page 50...
  • Page 51 PORTABLE LPV TREATER OUTLET CONVEYOR REST ASSEMBLY (13-05-0622) Item # Part # Description 05-03-1718 WDMT CNVR REST W/LK PORT 05-03-1719 WDMT CNVR REST W/LK PIVOT 05-03-1720 WDMT LATCH ROD 06-01-0025 BOLT .500-13 X 1.50 ZP GR5 06-01-0116 BOLT .375-16 X 2.75 ZP GR5 06-02-0015 NUT JAM .500-20 ZP GR5...
  • Page 52 THIS MATERIAL IS THE TOLERANCES CONFIDENTIAL AND FRACTIONS: +/- 1/8" TITLE: ASSY CNVR PIVOT SHEE PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE 6534 USA DWG#: 13-05-0 Page 52 USED WITHOUT PERMISSION. ANGLES: +/- 1°...
  • Page 53 PORTABLE LPV TREATER CONVEYOR PIVOT ASSEMBLY (13-05-0594) Item # Part # Description 05-03-1691 WDMT PIVOT PLT 06-03-0003 NUT NYL LOCK .375-16 ZP GR5 06-03-0014 NUT LOCK FLG .375-16 ZP GR5 06-05-0004 WSHR FLAT .375 ZP 06-06-0070 SCRW MACH .375-16 X 1.50 SH FLHD BO 06-06-0107 SCRW MACH .375-16 X 2.50 SH FLHD BO...
  • Page 54 PORTABLE LPV TREATER LPV PORTABLE PIVOT ASSEMBLY (13-05-0594) DETAIL A FILENAME: 13-05-0594B4 = LPV Cnvr Pivot 06/08/17 at 10:05 THIS MATERIAL IS THE TOLERANCES CONFIDENTIAL AND FRACTIONS: +/- 1/8" TITLE: ASSY LPV PORT PIVOT SHEET 2 OF 3 PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031...
  • Page 55 PORTABLE LPV TREATER LPV PORTABLE PIVOT ASSEMBLY (13-05-0594) Item # Part # Description 01-03-0060 BRG PLW SEALED 1.00ID STSC 02-06-0058 FTTG HYD 90 DEG 8MJ-8MOR 03-17-0133 CYL HYD 14IN STRK 3.0IN ID 05-03-1706 WDMT BOLT HLDR 05-03-1708 WDMT CYLN MNT LPV PORT...
  • Page 56 PORTABLE LPV TREATER INLET CONVEYOR INLET HOPPER ASSEMBLY (13-08-0540) Page 56...
  • Page 57 PORTABLE LPV TREATER INLET CONVEYOR INLET HOPPER ASSEMBLY (13-08-0540) Item # Part # Description 05-08-0477 WDMT LG INLET 8IN RND 05-08-0536 WDMT PIVOT BRSH PLT TS25 06-01-0004 BOLT, .250-20 X .500 UNC ZP GRADE 5 06-01-0115 BOLT CRG .375-16 X 1.00 ZP GR5 06-01-0124 BOLT FLG .375-16 X .750 ZP GR5...
  • Page 58 PORTABLE LPV TREATER INLET CONVEYOR INLET END ASSEMBLY (13-08-0532) Page 58...
  • Page 59 PORTABLE LPV TREATER INLET CONVEYOR INLET END ASSEMBLY (13-08-0532) Item # Part # Description 01-03-0042 BRG FLG MNT 1.000ID 2BOLT ECNTRC 01-08-0108 PULLEY TAIL W-LAGGING 05-08-0404 WDMT TAKE-UP PLT RND CNVR 05-08-0419 WDMT SPLICE 12IN 05-08-0569 WDMT TAIL TRANS TS25...
  • Page 60 PORTABLE LPV TREATER INLET CONVEYOR EXTENSION CLEAN OUT ASSEMBLY (13-08-0668) Item Num NOTES: RIVETN TO PR DIREC MAKE Page 60...
  • Page 61 PORTABLE LPV TREATER INLET CONVEYOR EXTENSION CLEAN OUT ASSEMBLY (13-08-0668) Item # Part # Description 05-08-0419 WDMT SPLICE 12IN 05-08-0461 WDMT TUBE 8.00IN X 84.86IN 05-08-0610 WDMT CLEAN OUT 05-10-4524 FRAME INLET SEC CLN OUT 06-01-0124 BOLT FLG .375-16 X .750 ZP GR5 06-01-0138 BOLT, FLG .3125-18 UNC ZP GRADE 5;...
  • Page 62 SPOUT SHOULD PIVOT FREELY AFTER ASSEMBLY. ADJUST SPOUT ANGLE AS NEEDED. PORTABLE LPV TREATER ADJUSTABLE DISCHARGE SPOUT ASSEMBLY (13-08-0705) Item Num Item # Part # Description 05-08-0661 WDMT SPOUT MNT 06-01-0006 BOLT .250-20 X .750 ZP GR5 06-05-0004 WSHR FLAT .375 ZP 06-05-0005 WSHR FLAT .500 ZP...
  • Page 63 PIN SHOULD ROTATE FREELY WHEN ASSEMBLED. LEAVE BEARING BOLTS LOOSE UNTIL TRACKING IS COMPLETE. USE ALIGNMENT HOLE FOR INITIAL SETTING, ADJUST TRACKING AS NEEDED. PORTABLE LPV TREATER HEAD TRACKING PLATE ASSEMBLY (13-08-0564) Item # Part # Description BRG FLG MNT 1.000ID 2BOLT ECNTRC...
  • Page 64 PORTABLE LPV TREATER INLET CONVEYOR HEAD SECTION ASSEMBLY (13-08-0737) Item Nu DETAIL A Page 64...
  • Page 65 PORTABLE LPV TREATER INLET CONVEYOR HEAD SECTION ASSEMBLY (13-08-0737) Item # Part # Description 01-03-0042 BRG FLG MNT 1.000ID 2BOLT ECNTRC 01-08-0109 PULLEY HEAD VULC TS2500 05-06-0131 COVER HD TS25 DD 05-08-0414 WDMT TUBE 8.00IN X 60IN 05-08-0529 WDMT LOCK PORT CNVR...
  • Page 66 PORTABLE LPV TREATER 17 FT INLET CONVEYOR ASSEMBLY (17-13-0028) Page 66...
  • Page 67 13-08-0653 KIT DRIVE 5HP DD TS25 13-08-0668 ASSY INLET EXT CLEAN OUT 13-08-0705 ASSY ADJ SPOUT TS CNVRS 13-08-0737 ASSY HEAD SECT TS2517 LPV-PORT SEE TABLE 1 CONVEYOR MOTOR TABLE 1 Conveyor Part # Motor Part # Conveyor Description 17-13-0028...
  • Page 68 PORTABLE LPV TREATER OUTLET CONVEYOR INLET HOPPER ASSEMBLY (13-08-0736) Page 68...
  • Page 69 Item # Part # Description 05-08-0536 WDMT PIVOT BRSH PLT TS25 05-08-0698 WDMT INLET HOP TS25 LPV PORT 06-01-0004 BOLT, .250-20 X .500 UNC ZP GRADE 5 06-01-0115 BOLT CRG .375-16 X 1.00 ZP GR5 06-01-0122 BOLT, CARRIAGE, .250-20x.75 G5 ZP 06-01-0124 BOLT FLG .375-16 X .750 ZP GR5...
  • Page 70 PORTABLE LPV TREATER OUTLET CONVEYOR INLET END ASSEMBLY (13-08-0710) Page 70...
  • Page 71 PORTABLE LPV TREATER OUTLET CONVEYOR INLET END ASSEMBLY (13-08-0710) Item # Part # Description 01-03-0042 BRG FLG MNT 1.000ID 2BOLT ECNTRC 01-08-0108 PULLEY TAIL W-LAGGING 05-08-0404 WDMT TAKE-UP PLT RND CNVR 05-08-0419 WDMT SPLICE 12IN 05-08-0569 WDMT TAIL TRANS TS25...
  • Page 72 PORTABLE LPV TREATER OUTLET CONVEYOR CLEAN OUT EXTENSION ASSEMBLY (13-08-0707) Item Number Page 72...
  • Page 73 PORTABLE LPV TREATER OULLET CONVEYOR CLEAN OUT EXTENSION ASSEMBLY (13-08-0707) Item # Part # Description 05-08-0419 WDMT SPLICE 12IN 05-08-0461 WDMT TUBE 8.00IN X 84.86IN 05-08-0610 WDMT CLEAN OUT 05-10-4576 FRAME INLET SEC CLN/OUT TS25 06-01-0124 BOLT FLG .375-16 X .750 ZP GR5 06-01-0138 BOLT, FLG .3125-18 UNC ZP GRADE 5;...
  • Page 74 PORTABLE LPV TREATER OUTLET CONVEYOR HEAD SECTION ASSEMBLY (13-08-0652) DETAIL A Page 74...
  • Page 75 PORTABLE LPV TREATER OUTLET CONVEYOR HEAD SECTION ASSEMBLY (13-08-0652) Item # Part # Description 01-03-0042 BRG FLG MNT 1.000ID 2BOLT ECNTRC 01-08-0109 PULLEY HEAD VULC TS2500 05-06-0131 COVER HD TS25 DD 05-08-0416 WDMT TUBE 8.00IN X 95.14IN 05-08-0549 WDMT MTR MNT PLT LG...
  • Page 76 PORTABLE LPV TREATER 20 FT OUTLET CONVEYOR BASE ASSEMBLY (13-08-0706) Page 76...
  • Page 77 PORTABLE LPV TREATER 20 FT OUTLET CONVEYOR BASE ASSEMBLY (13-08-0706) Item # Part # Description 05-06-0111 CVR SPLICE RND CNVR 8IN 05-06-0112 CVR SPLICE INLET RND CNVR 8IN 06-01-0261 BOLT FLG .3125-18 X .500 ZP GR5 09-01-0178 LBL ATWK TS2520...
  • Page 78 PORTABLE LPV TREATER 20 FT OUTLET CONVEYOR TOP ASSEMBLY Page 78...
  • Page 79 Page 79 FILENAME: THIS MATERIAL IS THE TOLERANCES U S C, CONFIDENTIAL AND L L C. FRACTIONS: +/- 1/8" TITLE: TS25 PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE Sabetha, Kansas 66534 USA...
  • Page 80 1058FF PLT CNVR LOCK LH 13-08-0653 KIT DRIVE 5HP DD TS25 13-08-0706 ASSY TS25 20FT BASE PORT 13-08-0736 ASSY INLET HOP TS25 LPV PORT SEE TABLE 1 CONVEYOR DRIVE MOTOR TABLE 1 Conveyor Part # Motor Part # Conveyor Description...
  • Page 81 PORTABLE LPV TREATER FILL HOPPER ASSEMBLY (13-04-0127) Item # Part # Description 05-03-0282 WDMT HOPP SMW DSCHG 05-07-0080 HOPP S2000 PORT FOR SMW 06-01-0189 BOLT FLG .375-16 X 1.250 ZP GR5 06-03-0014 NUT LOCK FLG .375-16 ZP GR5 Page 81...
  • Page 82 PORTABLE LPV TREATER LPV PORTABLE HARDWARE KIT (13-10-0055) Page 82...
  • Page 83 PORTABLE LPV TREATER LPV PORTABLE HARDWARE KIT (13-10-0055) DETAIL A DETAIL B DETAIL C Item # Part # Description Item # Part # Title 05-06-0109 ASSY CVR WIRE/HOSE GRD 05-06-0109 A ASSY CVR WIRE/HOSE GRD 05-06-0110 ASSY CVR WIRE/HOSE GRD...
  • Page 84 ANGL CLAMP SHORT FRACTIONS: +/- 1/8" TITLE: ASSY DAF MNT GOOSENECK PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE abetha, Kansas 66534 USA 106120 ANGLE CLAMP LONG USED WITHOUT PERMISSION. ANGLES: +/- 1°...
  • Page 85 U S C, CONFIDENTIAL AND L L C. FRACTIONS: +/- 1/8" TITLE: ASSY DAF MNT GOOSEN PROPRIETARY PROPERTY OF DECIMALS: X.XX +/- .06", X.XXX +/-.031 USC, LLC. AND SHALL NOT BE Sabetha, Kansas 66534 USA USED WITHOUT PERMISSION. ANGLES: +/- 1°...
  • Page 86 PORTABLE LPV TREATER DRY ADDITIVE FEEDER ASSEMBLY FILENAME: 13-05-0375A1 = LPV PORT DAF 03/26/18 at 11:32 TOLERANCES FRACTIONS: +/- 1/8" TITLE: DAF 2046 CS 84IN TUBE W CS BASE SHEET 1 OF 2 ECIMALS: X.XX +/- .06", X.XXX +/-.031 DWG#: 13-05-0375 MOD 26801 REV: MOD ANGLES: +/- 1°...
  • Page 87: Section J

    Section USC Limited Warranty USC, LLC, (Manufacturer) warrants its seed treating equipment as follows: 1. Limited Warranty: Manufacturer warrants that the Products sold hereunder will be free from defects in material and workmanship for a period of 18 months from date of shipment.
  • Page 88 PORTABLE LPV TREATER USC, LLC 2320 124th road Sabetha, KS 66534 PHONE: (785) 431-7900 FAX: (785) 431-7950 EMAIL: sales-team@uscllc.com WEB: www.uscllc.com Page 88...

Table of Contents