Adapter For Testing Extension Power Supply Cords (P 8030); Set Of Adapters Atp For Automatic Testing Extension Power Supply Cords (P 8080) - ILLKO REVEXmax S User Manual

Table of Contents

Advertisement

REVEXmax - User's Manual
7.4.2

Adapter for testing extension power supply cords (P 8030)

The adapter is designed to measure the continuity of the protective circuit extension
cords. It facilitates the work and significantly improves the contact of their PE pins.
Connect the banana plug adapter into the R
Test Socket 1 on the front panel REVEXmax and perform the test lead resistance
compensation of the adapter (see chapter 4.3.1).
Then connect the plug of the measured extension cord into Test Socket 1, lock the
measurement (see chapter 4.3) and plug the adapter into the socket of the tested
extension cord (Figure 36). The resistance of the PE circuit is now measured.
Figure 36: Adapter for testing extension power supply cords
7.4.3
Set of adapters ATP for automatic testing extension power supply
cords (P 8080)
The adapter set is used to measure the resistance of single-phase extension power
supply cords. The main advantage is that both ends of the extension power supply
cord need not be moved to the measuring instrument. The measurement procedure
is described in chapter 4.9.
The set includes two adapters:
ATP-A - connects to the device and to the extension power supply cord
ATP-B - connects to the extension power supply cord only
WARNING
Check that the extension power supply cord under test is not connected
to the mains!
If the ATP-B adapter displays a U
supply cord is connected to the mains - is required immediately dis-
connect the ATP-B adapter.
c 2019 ILLKO, s.r.o.
terminal, plug the adapter into
PE
warning, tested extension power
L-N
www.illko.cz