REVEXmax - User's Manual
connect the remaining current-carrying conductors by means of the test
lead + test tip to the instrument's R
If a Welding equipment output - Protective earth is measured, connect the
appliance for testing:
– For a one-phase or three-phase appliance with movable power supply
cord – connect the PE pin of its plug to the instrument's PE terminal
by means of the optional test lead + crocodile clip. Then connect the
welding equipment output to the instrument's R
means of the optional test lead + crocodile clip.
– For a hard-wired appliance – first disconnect the appliance from
the mains! Connect the point of the PE connection to the instrument's
PE terminal by means of the optional test lead + crocodile clip. Then
connect the welding equipment output to the instrument's R
terminal by means of the optional test lead + crocodile clip.
If a Mains - Welding equipment output is measured, connect the appliance for
testing:
– For a one-phase or three-phase appliance with movable power supply
cord – connect the current-carrying conductors by means of the test lead
+ test tip to the instrument's R
welding equipment output to the instrument's PE terminal by means of
the optional test lead + crocodile clip.
– For a hard-wired appliance – first disconnect the appliance from the
mains! Connect the current-carrying conductors by means of the test
lead + test tip to the instrument's R
the welding equipment output to the instrument's PE terminal by means
of the optional test lead + crocodile clip.
Switch on the tested appliance's mains switch.
Press the [TEST] key. It is recommended that you hold the [TEST] key
down for 5-10 seconds (or even longer if the displayed result is not stabilized);
the influence of the tested appliance's internal capacitance can be eliminated
by this method.
After finishing the measurement the last measured value is displayed.
c 2019 ILLKO, s.r.o.
/ I
ISO
/ I
ISO
ALT
/ I
ISO
www.illko.cz
4 Measurements
terminal.
ALT
/ I
terminal by
ISO
ALT
ISO
terminal. Then connect the
terminal. Then connect
ALT
/ I
ALT
Page 25

Advertisement

Table of Contents
loading

Related Products for ILLKO REVEXmax S

This manual is also suitable for:

Revexmax w

Table of Contents