KEB COMBIVERT G6 Programming Manual page 26

Control g6 analog / digital
Table of Contents

Advertisement

OPeRATOR PARAMeTeRS
Id-Text
os13
Meaning
Type
Data length
Access
Coding
Notice
Id-Text
os14
Meaning
Type
Data length
Access
Coding
Notice
26
Name
operator state
Shows the state of the power unit and the image of the power
unit parameter image of the control board.
Variable
8 bit
read
Bit 0
reserved
Bit 1...2
PU-conf.-ID state
Bit 3...5
PU-image state
Bit 6...15 reserved
Standard value: 0
-
Name
memory state
By writing of value "0" non-volatile parameters are saved imme-
diately.After completion of the storage the value jumps to status
"1".If at the end of the download lists in COMBIVIS the value "0"
comes before value "1", COMBIVIS will send the value as long
as the inverter finishes storing.
Variable
8 bit
read / write
0: busy
1: ready
2: off
Standard value: 1
-
Parameter index
0x208D
0: Power unit-ID unknown
2: Power unit-ID OK
4: Power unit-ID incorrect
0: PU-image not initialized
1: write PU-image
3: PU-image changed
4: PU-image initialized
5: PU-image check
6: PU-image not available
Parameter index
0x208E

Advertisement