KEB COMBIVERT G6 Programming Manual page 19

Control g6 analog / digital
Table of Contents

Advertisement

bASIC SeTTINGS
Id-Text
dp04
Meaning
Type
Data length
Access
Coding
Notice
Id-Text
dp05
Meaning
Type
Data length
Access
Coding
Notice
Name
Contrast
The contrast settings of the LC display can be changed to opti-
mize readability.
Variable
8 bit
read / write
0...50
Standard value: 21
-
Name
backlight
The contrast settings of the LC display can be changed to opti-
mize readability.
Variable
8 bit
read / write
0
off
Lighting of the LC display generally off.
1
on
Lighting of the LC display generally on.
2
auto
If the backlight is adjusted to "auto", it is
switched on during pressing a key and switched
off again after 10 seconds if no key is pressed.
Standard value: 2
-
Parameter index
0x2784
Parameter index
0x2785