Siemens SINUMERIK 840D sl Commissioning Manual page 16

Hmi-embedded im2
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Configuring the HMI system
2.3 Setting-up network connections
Type:
Connection:
Access level:
Note
You need the memory expansion (optional) to access the CompactFlash card. When the
option is set, the softkey is displayed: Memory card (CF) (supplied CompactFlash card with
Software HMI-Embedded)
see Accessories (Page 8)
1. Enter the other fields manually. You can choose any softkey text.
The following options are available for establishing connections:
Type name
No drive
Local USB
USB global
Flash card
NW Linux
NW Windows
● A numerical setting for DOS (Windows) is made in the "Partition" field.
● Two lines, with a maximum of nine characters each, are available for the softkey text.
● You must enter a user name and a password for Windows shares.
● No user names or passwords are needed for Linux (NFS) shares and local/global
16
No drive, USB local, USB global
Front (preassigned), X203, X204
1 Manufacturer
2 Service
3 User
4 Keyswitch setting 3
5 Keyswitch setting 2
6 Keyswitch setting 1
7 Keyswitch setting 0
Terminal
-
Front
(preassigned)
X203
X204
X203
X204
-
-
-
If you do not define a user, a standard user (PCU20_USER) will be entered and a
standard password used.
network paths (USB).
Path (path definition)
-
acttcu://0,2
acttcu://2
acttcu://1
.../user/sinumerik/data/...
// Linux ComputerName/Linux
ShareName
// WindowsComputername/Windows
ReleaseName
Commissioning Manual, 01/2008, 6FC5397-8CP10-1BA0
Connection to
TCU, to which the
device is connected
via USB.
Additional TCUs
CompactFlash card in
the NCU
A released directory in
a network drive. The
path name must start
with "//".
Commissioning HMI-Embedded (IM2)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de sl

Table of Contents