8.5 Remote diagnosis "RCS Host Embedded / RCS Viewer Embedded"
Option: "RCS service partner operates a Ping server" deactivated
This option should only be deselected if the initiative for remote diagnosis is to come from
the remote PC (e.g., if the remote PC and the NCU 7x0 are on the same intranet and an
individual NCU 7x0 on the LAN is accessed from a PC).
When this option is deactivated, no other entries are possible.
1. Press the "Save" softkey to complete the configuration of the server.
Connections for data exchange (file transfer)
In order to perform a file transfer, connection entries (\\<remote_ip>\<share folder name>)
are made automatically by the system for the remote diagnosis. These connection entries
are used by the "logical drives".
If none of the eight possible "logical drive" connections are free, switch to the "Start-up" area,
press the softkey "Connections" and delete a connection entry.
8.5.2

Configuring "RCS Viewer Embedded"

Requirement
● Remote diagnosis CD with the "RCS Viewer Embedded" software
● Logic drive for data exchange (file transfer)
Installation
1. Start installation of the remote diagnosis with "Setup.exe".
2. The following message appears:
3. Acknowledge the message.
Note
The Network Manager is not required with SINUMERIK 840D sI.
128
Commissioning HMI-Embedded (IM2)
Commissioning Manual, 01/2008, 6FC5397-8CP10-1BA0