Operation; References; System Clock - AVT MAGIC EEC Hardware & Software Manual

Eti/edi converter
Hide thumbs Also See for MAGIC EEC:
Table of Contents

Advertisement

W i n d o w s
P C
S o f t w a r e
P A G E 2 8
– MST CRC: This alarm is set if the CRC MST is faulty.
– Frame Counter: The frame counter is not continuous.
– Frame Phase: The frame phase is not continuous.
– Frame Length: The indicated frame length is wrong.
– LI TIST: The LI TIST is not continuous.
The number of Audio and Data subchannels is displayed under No. Sub-
chan. (Number of Subchannels).
Under FIC included you can see if the Fast Information Channel (FIC) is in-
cluded into the ETI data stream.
Also displayed are the DAB Mode and the Frame Length.
4.5.2.3

Operation

The operation mode of MAGIC EEC is indicated under Mode.
Additionally, the following status messages are displayed:
– Time Reference Sync: This LED shows when the newly generated time
information (time reference and TIST) is valid.
4.5.2.4

References

Under References the following alarms and status messages are indicated:
– NTP: Display of the IP address of the connected NTP Server. The alarm is
set if both NTP servers are not available.
– 1 PPS: The 1 pps clock is faulty.
– Clock 2: 10 MHz or 2,048 MHz: The reference clock is faulty.
4.5.2.5

System Clock

Here it is indicated which system clock is currently used.
– Clock 2: 10 MHz or 2,048 MHz (see CHAPTER 4.7.2.1.1, Page 35)
– Internal