4.7.2.1.3

E1 Interface

The menu item E1 Interface allows a configuration of the E1 parameters.
FIG. 10
E1 Parameters
• Please select the Format of your E1 (2-Mbit/s) network. You can choose
between Double Frame and CRC Multi Frame.
NOTE
This selection depends on the network and is a setting in the last E1 transmis-
sion equipment before it is connected to the converter. All countries except
Germany are normally using Double Frame format. If you select the wrong
format you will get immediately signal errors.
In case you do not know which E1 (2-Mbit/s) format you use, please ask your
network provider.
• Via the option Disable E1 Output Alarms of E1 Module 2 (ETI Monito-
ring Output), you can deactivate the output alarms for the E1 Interface 2.
If you select this option, the alarms will be no longer displayed in the main
window.
ETI
• Please select which ETI Format you use. MAGIC EEC supports G.704 NA
5592, G.704 NA 5376 and G.703 NI.