INDEX Introduction ....................... 4 Conventions ....................5 Safety ......................5 General safety requirements ................ 6 Construction ....................7 Functionality ....................8 Putting The System into operation ..............9 Mounting ...................... 9 Connection to the mains voltage ..............10 Operational elements at the front side............11 Front status LEDs ..................
INTRODUCTION MAGIC EEC allows the conversion from ETI to EDI and EDI to ETI signals. Typical applications are Ensemble Multiplexers, which cannot generate an ETI signal anymore (e. g. Fraunhofer ContentServer), but which must be fed to the transmitter via E1 lines with ETI or Ensemble Multiplexers, which only have ETI inputs/outputs (e.
Conventions In this manual the following conventions are used as text markers: The Tip symbol marks information which facilitates the operation of the system in its daily use. The Note symbol marks general notes to observe. The Attention symbol marks very important advice that is absolutely to observe. In case of non-observance malfunctions and even system errors are possible.
General safety requirements To keep the technically unavoidable residual risk to a minimum, it is absolutely necessary to observe the following rules: Transport, storage and operation of the unit must be under the • permissible conditions only. • Installation, configuration and disassembly must be carried out only by trained personal based on the respective manual.
The functions of the system are implemented in a 19” x 1U housing, the dimensions are 434 mm x 44,5 mm x 260 mm. MAGIC EEC can be used as a table-top device or it can be mounted in 19" racks. The 19” mounting brackets are included in delivery.
Via the integrated SNMP agent, which supports the SNMP v1/v2 protocols, control of the system can be realised for up to four independent network management systems. With the optional SDC upgrade a MAGIC EEC system can be upgraded to a full MAGIC SDC Switch & Converter. Options •...
With its dimensions of (width x height x depth) 434 mm x 44.5 mm (1U) x 260 mm the MAGIC EEC system can either be used as desktop device or mounted into a 19- inch rack. 19“mounting brackets are included in delivery. When mounting the unit please keep in mind that the bending radius of the connected cables is always greater than the minimum allowed value.
Connection to the mains voltage Attention! High touch current possible! Before connecting the power supply, MAGIC EEC must be earthed. For this purpose, the earthing cable must have a conductor cross-section of at least 2.5mm² if it is mechanically protected, or otherwise 4.0mm².
Operational elements at the front side The system has an illuminated graphical display with a resolution of 160 x 32 pixel and 19 operating buttons. On the right next to the display there are two softkeys whose current functions are indicated on the display.
Wiring MAGIC EEC has an ETI module and can be extended with a second ETI module or the Dual LAN Upgrade. A redundant power supply is also available as an option. Second ETI Module (optional) Redundant power supply 2 x LAN...
On the front side of the unit 5 LEDs for status indication are available. The connectors for the interfaces are at the rear side of the unit. MAGIC EEC front view MAGIC EEC rear view with optional redundant power supply...
Control and data interfaces 3.2.1 Ethernet interfaces LAN 1 / LAN 2 The LAN 1 and LAN 2 interfaces can be used as control interfaces. One of the two interfaces can also be used to connect it to an NTP Server. Additionally, it can be used as EDI input.
3.2.2 TTL/Relay interface The TTL/relay interface is realised as a 25-pin socket. It provides eight TTL inputs/outputs as well as eight relay contacts. This interface can be used for external signalling of alarms. The programming of the available functions is possible via the Windows PC Software.
Network interfaces 3.4.1 E1 (2-Mbit/s) interface (Module Slot 1 and/or 2) With the ETI module, the system provides an ETI input/output. In addition, either a second ETI module or the Dual LAN module can be equipped. The following options are possible: Monitoring Output if two ETI modules are installed or EDI/ETI converting if the EDI upgrade is available.
100 – 230 V AC, 50 – 60 Hz, auto adjusting, max. 30 W 3.5.2 Optional DC power supply socket Only use the +5 V DC power supply provided by AVT. Pin assignment: 5 V power supply socket Socket: KYCON KPJ-S4...
TECHNICAL DATA Line interfaces: • E1 (ETI) 2.048-MHz, G.703/G.704 LAN (EDI) 10/100 Base-T, RJ45 • Standards: • ETSI ETS 300 799 (ETI) ETSI TS 102 693 (EDI) • Control interfaces: 2 x Ethernet 10/100 Mbit/s • Optional: Dual LAN Upgrade •...
Page 20
Display: • Graphical, resolution 160 x 32 pixels • Illuminated (can be switched off) Power supply: • Integrated power supply: 100 – 230 V Power max. 30 W • Redundant external power supply (opt.): +5 V Power max. 30 W Power consumption: •...
If your unit is defective, please contact us before sending in the device. To send in the system please fill in the included Service Request and send the unit to the following address: AVT Audio Video Technologies GmbH - Repairs - Nordostpark 91 90411 NÜRNBERG...
The device contains valuable raw materials that can be recycled. For proper recycling, send the device to us: AVT Audio Video Technologies GmbH - Recycling - Nordostpark 91 90411 NÜRNBERG GERMANY WEEE Reg.
EU-Konformitätserklärung EU-Declaration of Conformity Name des Anbieters: AVT Audio Video Technologies GmbH Supplier’s name: Anschrift des Anbieters: Nordostpark 91 Supplier’s address: 90411 Nürnberg Germany erklärt, dass das Produkt declares, that the product Produktname(n): MAGIC EEC ETI/EDI Converter 800890 Product name(s): mit den Vorschriften folgender Europäischer Richtlinien übereinstimmt:...