– Error Level 1: This LED indicates that the Error Level is 1.
– Error Level 2: This LED indicates that the Error Level is 2.
– Error Level 3: This LED indicates that the Error Level is 3.
– Header CRC: This alarm is set if the CRC header is faulty.
– MST CRC: This alarm is set if the CRC MST is faulty.
– Frame Counter: The frame counter is not continuous.
– Frame Phase: The frame phase is not continuous.
– Frame Length: The indicated frame length is wrong.
– LI TIST: The LI TIST is not continuous.
The number of Audio and Data subchannels is displayed under No. Sub-
chan. (Number of Subchannels).
Under FIC included you can see if the Fast Information Channel (FIC) is in-
cluded into the ETI data stream.
Also displayed are the DAB Mode and the Frame Length.
4.5.3.3
E1 Output
The following alarms are displayed under E1 Output. Next to the LEDs you
can see the number of the occured alarms.
– Output open: There is no further processing unit.
– Output shorted: 2-Mbit/s output is shorted.
4.5.3.4
Interface 2: E1 Output (monitoring output)
NOTE
This information will only be displayed if your MAGIC EEC system has the
optional Monitoring Output (system version ID 800891).
The following alarms are displayed under Interface 2: E1 Output (monito-
ring output). Next to the LEDs you can see the number of the occured alarms.
– Output open: There is no further processing unit.
– Output shorted: 2-Mbit/s output is shorted.
TIP
The output alarm messages can be disabled for Interface 2 under Configu-
→
ration
System
→
→
Operation Settings
E1 Interface.