Putting The Magic Acx Into Operation; Mounting - AVT MAGIC ACX Dante WAN Hardware Manual

Table of Contents

Advertisement

2

PUTTING THE MAGIC ACX INTO OPERATION

2.1

Mounting

With its dimensions of (width x height x depth) 434 mm x 44.5 mm (1U) x 270 mm
the MAGIC ACX system can either be used as desktop device or mounted into a 19-
inch rack. 19"mounting brackets are included in delivery. When mounting the unit
please keep in mind that the bending radius of the connected cables is always
greater than the minimum allowed value.
When the MAGIC ACX is installed, please make sure that there is sufficient cooling:
It is recommended to keep a spacing of ca. 3 cm from the openings. In general, the
ambient temperature of the system should be within the range of +5 °C and +45 °C.
These thresholds are specially to observe if the system is inserted in a rack. The
system works without ventilation.
The system temperature can be indicated on the display under MENU > STATUS
INFORMATION > DEVICE TEMPERATURE or in the software under Extras > System
Monitor > System Temperature.
During operation humidity must range between 30% and 85%.
Incorrect ambient temperature and humidity can cause functional deficiencies.
Improper use of the unit can lead to a loss of warranty claim.
9

Advertisement

Table of Contents
loading

Table of Contents