4.5.3
The MAGIC EEC main window - EDI to ETI Converter
To operate the MAGIC EEC as EDI Switch, please select under Configuration
→
System
tion EDI to ETI Converter (see CHAPTER 4.7.2.1.1, Page 35).
FIG. 4
4.5.3.1
EDI Input
The following alarms are displayed under EDI Input if the system is operated
as EDI Switch. Next to the LEDs you can see the number of the occured
alarms.
– Signal: No EDI signal is received.
– PFT Sync: This alarm is set if the PFT Sync is faulty.
– PFT CRC: This alarm is set if the PFT CRC is faulty.
4.5.3.2
ETI
Directly below the ETI bar it is displayed if and when a reconfiguration is
pending.
In the next line the name of the Ensemble is shown followed by the detected
Format.
Additionally, the following alarms and status messages are displayed:
– ETI Framing: This alarm occurs if the ETI frame cannot be found.
– Error Level 0: This LED indicates that the Error Level is 0.
→
→
Operation Settings
MAIN WINDOW - EDI TO ETI CONVERTER