Relay/Ttl - AVT MAGIC EEC Hardware & Software Manual

Eti/edi converter
Hide thumbs Also See for MAGIC EEC:
Table of Contents

Advertisement

W i n d o w s
P C
S o f t w a r e
P A G E 4 0
4.7.2.2.1

Relay/TTL

The MAGIC EEC has eight GPIO Pins (TTL) which can be programmed in-
dividually. Furthermore, eight relays are also available.
The following description applies to all eight configuration windowsTTL 1
(Pin 1), TTL 2 (Pin 2), TTL 3 (Pin 3), TTL 4 (Pin 4), TTL 5 (Pin 5), TTL 6 (Pin
6), TTL 7 (Pin 7) and TTL 8 (Pin 8).
TTL Pin as Output
ATTENTION
Please note that the maximum switching current is 10 mA and the maximum
switching voltage is 3.3V per TTL output.
!
FIG. 12
If a TTL Pin is configured as an Output, the event is signalled when the volt-
age at the TTL Pin changes from 0V to +3.3V.
Under Positive edge you can select the following Function Codes:
– Fixed Low: The TTL Pin is fixed to 0V.
– Fixed High: The TTL Pin is fixed to +3.3V.
– Information Base Entry: Special function for projects
– System Alarm Pending: This function signals a pending system alarm
(see CHAPTER 4.9.1).
– Application Alarm Pending: This function signals a pending application
alarm. You can select up to three specific alarms or the options Any Clock
Alarm or Any input Alarm.
TTL PIN AS OUTPUT

Advertisement

Table of Contents
loading

Table of Contents