Interfaces

3.9 Measuring sockets

3.9
Measuring sockets
Application
The measuring sockets X141 (T0, T1 and T2) are on the lower side of the module and are
used to output analog signals. Any interconnectable signal can be output via SINAMICS on
every measuring socket on the control unit.
Interface assignment
Table 3- 19
The measuring sockets are suited for multiple-spring wire connectors with a diameter of 2 mm.
Note
The measuring sockets support commissioning and diagnostic functions. Connection for
normal operation is not permitted.
Measuring socket position
Figure 3-10
70
Measuring sockets T0, T1, T2
Socket
T0
T1
T2
M
Measuring socket position
Function
Technical specifications
Measuring socket 0
Voltage: 0 V to 5 V
Resolution: 8 bits
Measuring socket 1
Load current: Max. 3 mA
Measuring socket 2
Continuous short-circuit-proof
Ground
Reference potential is G terminal
x 191
SIMOTION D4x5-2
Manual, 02/2012