Supplementary system components
6.5 CX32-2 controller extension
Communication
Table 6- 32
Data
DRIVE-CLiQ interfaces
General technical data
Table 6- 33
Data
Power supply
Current consumption, typically
Starting current, typical
Power loss, typical
Power loss, max.
With no load on I/Os, no 24 V supply via DRIVE-CLiQ interface
1)
Digital inputs
Table 6- 34
Data
Digital inputs
Galvanic isolation
Current consumption typ. at High level
Input delay, typical (hardware)
The reference potential is terminal M1
1)
The digital inputs are protected against polarity reversal up to -30 V
2)
126
Interface communication
Technical data (general)
Rated value
Permissible range
Digital inputs on SIMOTION CX32-2
Rated value
For signal "1"
For signal "0"
2)
SIMOTION CX32-2
4
SIMOTION CX32-2
24 VDC
(20.4 ... 28.8 V)
300 mA
1)
1.6 A
7 W
14 W
SIMOTION CX32-2
6
24 VDC
15 ... 30 V
-3 ... +5 V
Yes, in groups of 6
1)
9 mA at 24 V
L -> H: 50 µs
H -> L: 150 µs
SIMOTION D4x5-2
Manual, 02/2012