3.3 Ethernet interfaces
Interface characteristics
Table 3- 5
X127 P1 and X130 P1 (X120 P1 only for SIMOTION D4x5-2 DP)
Characteristic
Connector type
Cable type
Max. cable length
Autocrossing
Dust protection blanking plugs for
sealing unused Ethernet ports
Miscellaneous
Pin assignment
Table 3- 6
X127 P1 and X130 P1 Ethernet interfaces (X120 P1 only for SIMOTION D4x5-2 DP)
Representation
Pin
1
2
3
4
5
6
7
8
I = Input; O = Output; B = Bidirectional
Autocrossing functionality (if required, transmit and receive lines switch over)
1)
Note
The MAC addresses are imprinted on an adhesive label that is located behind the protective
cover and can be seen from the front.
54
Type
RJ45 socket connector
Industrial Ethernet cable
4- and 8-wire cables can be used for 10/100 Mbit/s
8-wire cables must be used for 1000 Mbit/s
100 m
Yes
Five blanking plugs contained in the D4x5-2 scope of delivery
Blanking plugs (50 pcs) order number: 6SL3 066-4CA00-0AA0
X127 P1, X120 P1 and X130 P1 are full-duplex 10/100/1000 Mbit/s Ethernet ports
Assignment in 10/100 Mbit mode
Signal
Signal type
name
1)
TXP
O
TXN
O
RXP
I
- - -
- - -
- - -
- - -
RXN
I
- - -
- - -
- - -
- - -
Meaning
Ethernet transmit
differential signal
Ethernet transmit
differential signal
Ethernet receive
differential signal
Reserved, do not use
Reserved, do not use
Ethernet receive
differential signal
Reserved, do not use
Reserved, do not use
Assignment in 1 Gbit mode
Signal
Signal type
Meaning
name
1)
DA+
B
Bidirectional pair A+
DA-
B
Bidirectional pair A-
DB+
B
Bidirectional pair B+
DC+
B
Bidirectional pair C+
DC
B
Bidirectional pair C-
DB-
B
Bidirectional pair B-
DD+
B
Bidirectional pair D+
DD-
B
Bidirectional pair D-