Technical data of the D4x5-2

4.4 Power supply

4.4
Power supply
External 24 V power supply
The control unit is supplied by an external 24 V power supply (e.g. SITOP).
The tolerance range for the input voltage of the SIMOTION D4x5-2 is between 20.4 and
28.8 VDC.
Table 4- 5
Power supply data
Power supply
Rated value
Permissible range
Current consumption, typically
Starting current, typically
Power loss, typically
1)
With no load on inputs/outputs, no 24 V supply via DRIVE-CLiQ and PROFIBUS interfaces
1)
Table 4- 6
Input voltage specification
Input voltage
Minimum input voltage
Nominal input voltage
Maximum input voltage
Table 4- 7
Specification of the input current - typical current consumption
Device type
Minimum input voltage
Nominal input voltage
Maximum input voltage
With no load on inputs/outputs and no 24 V supply via DRIVE-CLiQ or PROFIBUS interface
1)
78
D425-2 DP
D435-2 DP
Safety extra-low voltage DVC A (PELV)
24 VDC
(20.4 ... 28.8 V)
0.7 A
1)
5 A
1)
17 W
Typical current consumption
D425-2 DP
D435-2 DP
0.8 A
0.7 A
0.6 A
D425-2 DP/PN
D435-2 DP/PN
1.0 A
5 A
24 W
D4x5-2
20.4 V
24 V
28.8 V
1)
D425-2 DP/PN
D435-2 DP/PN
1.2 A
1.0 A
0.8 A
D445-2 DP/PN
D455-2 DP/PN
1.9 A
5 A
46 W
D445-2 DP/PN
D455-2 DP/PN
2.24 A
1.9 A
1.58 A
SIMOTION D4x5-2