3.8

Measuring sockets

Properties
The T0 - T2 measuring sockets are used to output analog signals. Any interconnectable
signal can be output via SINAMICS on every measuring socket on the control unit.
Note
The measuring sockets are suited for multiple-spring wire connectors with a diameter of
2 mm.
Interface characteristics
Table 3- 23
Characteristic
Connector type
Voltage
Resolution
Load current
Sustained short-circuit proof
Reference potential is M terminal
Interface assignment
Table 3- 24
Representation
SIMOTION D410-2
Manual, 02/2012
T0, T1 and T2 interfaces
Type
2 mm sockets
0 V to 5 V
8-bit
max. 3 mA
Interface assignments T0, T1 and T2
Pin
T0
T1
T2
M
Designation
Measuring socket 0
Measuring socket 1
Measuring socket 2
Ground