Safety data sheet Océ VarioPrint 2070
PRODUCT SAFETY DATA SHEET
Océ-(UK), Ltd
Model
Description
Process speed
Dimensions
Weight
Voltage
Frequency
Current-rated
Building fuse
Power consumption, stand by
Power consumption, operation
EPA
E
NERGY
* Power consumption,
* Power consumption,
Mains connection
Safety class
Protection class
Sound pressure level
(at operator position)
Sound power level
Radio interference
Radiation
Heat emission
Ozone emission
Room volume
Room ventilation
Use simulation at random
operation
Consumables
Additional safety information
CE-Compliance
Copyright © 2002 Océ-Technologies B.V., Venlo, NL
The content of this safety data sheet is subject to the disclaimer of liability (see
'Disclaimer') of this manual.
152
Océ VarioPrint 2050-70 Job manual
Océ VarioPrint 2070
Electrostatic digital copier/printer, console model, plain paper, organic photoconductive belt,
powder toner, automatic duplexing
62 A4 prints/min or 31 A3 prints/min
Width
Depth
Height
®
S
TAR
sleep mode
low-power
Cable with plug
I
IP 20
Standby
Lp(A) = 35 dB(A)
Lw(A) = 48 dB(A)
Complies with Directive 89/336/EEC and FCC rules and regulations, part 15 Class A.
Below the Threshold Limit Values for UV, Visible and IR radiation (TLV list of ACGIH)
Standby 405 W; in operation 1,8 W
0,01 mg/min at continuous operation
Recommendation: min. 30 m
Recommendation: min. 15 m
For heat evacuation extra ventilation may be necessary.
Room volume and ventilation as recommended
Daily copy volume (much more than average)
Total worktime
Ozone concentrations:
- Time weighted average
- Peak
Threshold Limit Value/Occupational Exposure Limit
(Time Weighted Average) for ozone
Odour Perception Limit for ozone
Océ Master (Océ Material Safety Data Sheet E-193)
Océ F11 Toner (Océ Material Safety Data Sheet E-212)
Océ Copying Materials
This apparatus is suitable for processing recycling paper which complies with the
requirements of DIN 19309.
The ozone filter does not have to be replaced for keeping the ozone concentration in the
workplace below 0,04 mg/m
Approved according to
Low Voltage Directive
73/23/EEC
1720 mm
900 mm (incl. spacers)
1386 mm
415 kg
230 V
50 Hz
8 A
16 A
405 W (total system)
1,8 kW (total system)
72 W (total system)
235 W (total system; recovery time <10 s)
(IEC 536) Protective earth connection
(IEC 529)
3
3
/h (natural ventilation)
3
(the life of the filter equals that of the apparatus).
Approved according to
EMC Directive
89/336/EEC
Number
Date
Digital Access Controller
390 mm
432 mm
108 mm
11 kg
230 V
50 Hz
0,5 A
3 A
In operation
mainbody Lp(A) = 59 dB(A);
incl. optionals Lp(A) = 64 dB(A);
impulse
L
= 4 dB(A)
i
mainbody as Lw(AI) = 78 dB(A);
11250 A4
8 h
3
0,001 mg/m
3
0,003 mg/m
3
0,2 mg/m
3
0,04 mg/m
EPA
E
NERGY
E-759-a-UK
September 2002
(0.0005 ppm)
(0.0015 ppm)
(0,1 ppm)
(0,02 ppm)
®
S