Gree GMV5 Series Service Manual page 100

Dc inverter vrf units
Hide thumbs Also See for GMV5 Series:
Table of Contents

Advertisement

32
Inlet-tube temperature of condenser
Note:
If a parameter value is negative, LED3 circularly displays the negative code "nE‖ and the numeric value
every one second. For example, for -30C, LED3 alternately displays ―nE‖ for one second and then ―30‖
for another second.
The discharge temperature and environment temperature are displayed as four-digit values, circularly
displaying the higher two digits and the lower two digits. For example, if "01" and "15" are alternately
displayed, it indicates 115C. If "nE", "00", and "28" are alternately displayed, it indicates -28C.
If a parameter is invalid for the unit, ―00‖ is displayed.
If no button operations are performed on the master unit for five minutes, the function setting
automatically quits and the unit restores the current status.
Step 9: If the nb ODU bar code query is selected, the display is as follows. Enter the to-be-confirmed
status of ODU bar code query.
LED1
Function Code
Display Mode
nb
Press "SW7" on the master unit to enter the next-level menu selection. The display is as follows:
LED1
Function Code
nb
nb
nb
nb
Select a module for query by pressing "SW1 (▲)" or "SW2 (▼)" and then press "SW7". The display is as
follows:
LED1
Function Code
nb
Note: Un indicates the entire-unit bar code and Pc indicates the controller bar code.
After confirming the module, select a bar code sequence by pressing "SW1 (▲)" or "SW2 (▼)". The
display sequence is as follows:
Entire-unit bar code (bits 1-13) and controller bar code (bits 1-13), that is, entire-unit bar code header →
entire-unit bar code (bits 1-6) → entire-unit bar code (bits 7-12) → entire-unit bar code (bit 13) →
controller bar code header → controller bar code (bits 1-6) → controller bar code (bits 7-12) → controller
bar code (bit 13). The display is as follows:
LED1
Parameter Code
Code
Example:
Entire-unit bar code: N1R0128150066
Controller bar code: N1M0128150067
The display sequence is as follows:
LED1
Parameter Code
nb
GMV5 DC INVERTER VRF UNITS SERVICE MANUAL
Current Progress/Mode
Blinking
00
Display Mode
Module Address
On
01
On
02
On
03
On
04
Display Mode
Parameter Code
On
Un/Pc
Display Mode
Parameter Code
On
Code
Display Mode
Parameter Code
On
Un
This parameter is invalid for the
° C
LED2
Display Mode
Blinking
LED2
Display Mode
Current Status
Blinking
Blinking
Blinking
Blinking
LED2
Display Mode
Current Status
Blinking
LED2
Display Mode
Parameter Code
On
LED2
Display Mode
Parameter Code
Blinking
97
GMV5 series.
LED3
Current Status
Display Mode
00
Blinking
LED3
Display Mode
00
Blinking
00
Blinking
00
Blinking
00
Blinking
LED3
Display Mode
-n
Blinking
LED3
Display Mode
Code
On
LED3
Display Mode
-n
Blinking

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents