IBM Power Systems 9008-22L Manual page 85

Power systems, system processor modules
Hide thumbs Also See for Power Systems 9008-22L:
Table of Contents

Advertisement

Note: Some service action events remain open when you leave this MAP. Further service actions
might be required to complete the repair.
11. Examine the details of this service action event, and record the partitions that are involved in this
service action event for use in a later step.
12. Is the error code associated with this service action event of the form A11-xxx or A01-xxx?
v Yes: Continue with the next step.
v No: Go to step 17.
13. Have you begun a list of Axx partitions from prior service action events that you processed in this
MAP?
v Yes: Go to step 15.
v No: Continue with the next step.
14. Begin a new list of Axx partitions by copying the list of partitions that are obtained in step 11. Go to
step 16.
15. Add the partition list that is obtained in step 11 to the existing list of Axx partitions that are obtained
from processing previous service action events in this maintenance analysis procedure (MAP).
16. Remove all entries in the list of all partitions you recorded in step 11. If you are referred to the list of
partitions that are obtained in step 11 in future steps, the list is empty. Go to step 17.
17. Select and highlight the service action event from the Error Associated With This Serviceable Event
window.
18. Click Close Event.
19. Add comments for the serviceable event. Include any unique additional information. Click OK. The
following steps add or update FRU information.
20. Did you replace, add, or modify a FRU of the open service action event?
v Yes: Continue with the next step.
v No: Go to step 22.
21. From the FRU list, select a FRU that you need to update. Double-click the FRU, and update the FRU
information. Go to step 23.
22. Select the No FRU Replaced for this Serviceable Event option.
23. Click OK to close the service action event.
24. Is the list of all partitions you recorded in step 11 empty?
v Yes: Go to step 32 on page 70.
v No: Continue with the next step.
25. Does the list of all partitions you recorded in step 11 contain more than one entry?
v Yes: Continue with the next step.
v No: Go to step 32 on page 70.
26. Is the error class recorded in step 25 AIX?
v Yes: Continue with the next step.
v No: Go to step 32 on page 70.
27. Perform all the following steps for each entry in the list of all partitions you recorded in step 11,
except for the partition you were using to debug the original problem.
28. From the list of all partitions, open the HMC virtual terminal window of a partition, and then type
diag at the AIXcommand prompt.
29. When the diagnostic operating instructions are displayed, complete the following steps:
a. Press Enter.
b. Select the Task Selection option.
c. Select the Log Repair option.
d. Select the resource that is associated with the repair action:
Common procedures for removing or replacing the system processor module
69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power systems 9009-22aPower systems 9223-22hPower system 9009-22aPower system 9008-22lPower system 9223-22h

Table of Contents