IBM Power System 9009-41G Manual
IBM Power System 9009-41G Manual

IBM Power System 9009-41G Manual

Sas subsystem
Hide thumbs Also See for Power System 9009-41G:

Advertisement

Quick Links

Power Systems
SAS subsystem for the 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9009-41A, 9009-41G, 9009-42A,
9009-42G, 9223-22H, 9223-22S,
9223-42H, or 9223-42S
IBM

Advertisement

Table of Contents
loading

Summary of Contents for IBM Power System 9009-41G

  • Page 1 Power Systems SAS subsystem for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 11, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    SAS subsystem base function storage configuration with the split-disk feature.........9 SAS subsystem expanded function configuration.................9 SAS subsystem service considerations.....................10 Problem determination and recovery....................... 10 Notices........................11 Accessibility features for IBM Power Systems servers................12 Privacy policy considerations ........................13 Trademarks..............................13 Electronic emission notices........................13 Class A Notices............................. 13 Class B Notices.............................17...
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 – For racks with a DC power distribution panel (PDP), connect the customer’s DC power source to the PDP. Ensure that the proper polarity is used when attaching the DC power and DC power return wiring. • Connect any equipment that will be attached to this product to properly wired outlets. •...
  • Page 7 • Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). •...
  • Page 8 • (For fixed drawers.) This drawer is a fixed drawer and must not be moved for servicing unless specified by the manufacturer. Attempting to move the drawer partially or completely out of the rack might cause the rack to become unstable or cause the drawer to fall out of the rack. (R001 part 2 of 2) CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation.
  • Page 9 DANGER: Rack-mounted devices are not to be used as shelves or work spaces. Do not place objects on top of rack-mounted devices. In addition, do not lean on rack-mounted devices and do not use them to stabilize your body position (for example, when working from a ladder). Stability hazard: •...
  • Page 10 DANGER: Multiple power cords. The product might be equipped with multiple AC power cords or multiple DC power cables. To remove all hazardous voltages, disconnect all power cords and power cables. (L003) (L007) CAUTION: A hot surface nearby. (L007) x Power Systems: SAS subsystem...
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 • LIFT TOOL intended for use to assist, lift, install, remove units (load) up into rack elevations. It is not to be used loaded transporting over major ramps nor as a replacement for such designated tools like pallet jacks, walkies, fork trucks and such related relocation practices. When this is not practicable, specially trained persons or services must be used (for instance, riggers or movers).
  • Page 13 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 14 xiv Power Systems: SAS subsystem...
  • Page 15: Sas Subsystem

    5105-22E, IBM Power System L922 (9008-22L), IBM Power System S922 (9009-22A and 9009-22G), IBM Power System H922 (9223-22H), IBM Power System H922S (9223-22S), IBM Power System S914 (9009-41A and 9009-41G), IBM Power System S924 (9009-42A and 9009-42G), IBM Power System H924 (9223-42H), or IBM Power System H924S (9223-42S) servers.
  • Page 16 Table 1. SAS subsystem parts in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems with the base function storage configuration Customer card Diagram identification numbers location Part name Feature code (FC) (CCINs) Physical location codes PCIe3 x8 SAS RAID internal EJ1F 57D7 P1-C49...
  • Page 17 Figure 3. SAS subsystem parts in the base function storage configuration with the split-disk feature in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S system Table 3. SAS subsystem parts in 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S systems with the base function storage configuration with split-disk feature Customer card Diagram...
  • Page 18 Figure 4. SAS subsystem parts in systems with base function storage configuration with the split-disk feature in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S Table 4. SAS subsystem parts in 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S systems with the base function storage configuration with split-disk feature Customer card Diagram...
  • Page 19 Figure 5. SAS subsystem parts in a system with expanded function storage configuration in a 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S Table 5. SAS subsystem parts in a 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S system with the expanded function storage configuration Customer card Diagram...
  • Page 20 Figure 6. SAS subsystem parts with the expanded function storage configuration in a 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S system Table 6. SAS subsystem parts in a 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, or 9223-42S system with the expanded function storage configuration Customer card Diagram...
  • Page 21: Sas Architecture

    – Optimized skip read/write disk support for transaction workloads Related information Serial-attached SCSI cable planning SAS RAID controllers for AIX SAS RAID controllers for IBM i SAS RAID controllers for Linux SAS architecture Serial-attached SCSI (SAS) architecture describes a serial device interconnection and transportation protocol that defines the rules for information exchange between devices.
  • Page 22: Sas Subsystem Storage Configurations

    SAS subsystem storage configurations Several SAS subsystem storage configurations are supported on the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S systems. The configuration you use depends on the combination of SAS features that you have installed on your system.
  • Page 23: Sas Subsystem Base Function Storage Configuration With The Split-Disk Feature

    • Two 8x mini SAS HD cables The base function storage configuration for 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-42H, and 9223-42S systems includes: • One PCIe3 x8 SAS RAID internal adapter 6 Gb, with RAID 0,10,5,6 • One base function disk drive backplane that supports 12x SFF (2.5") bays •...
  • Page 24: Sas Subsystem Service Considerations

    • Physical disk locations • Path to your boot device Related information Logical partitioning SAS RAID controllers for IBM i SAS RAID controllers for Linux SAS RAID controllers for AIX Problem determination and recovery Review information about using problem determination and recovery procedures for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9009-41A, 9009-41G, 9009-42A, 9009-42G, 9223-22H, 9223-22S, 9223-42H, or 9223-42S system.
  • Page 25: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 26: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 27: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 28 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 29 Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
  • Page 30 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 31: Class B Notices

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 32 Tel: +49 (0) 800 225 5426 email: HalloIBM@de.ibm.com Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55032 Klasse B Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase.
  • Page 33: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 34 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed.
  • Page 36 IBM®...

Table of Contents