Note: If, during the processing of the list of open service action events, some service action events
remained open, further service actions might be required to complete the repair.
Return the server to the state that the customer normally uses, such as IPL type, IPL mode, and the
way the system is configured or partitioned. This might require you to reboot the operating system.
7. Complete the following steps:
a. Restart the system.
b. Wait until the AIX operating system login prompt is displayed or until system activity on the
operator panel or display stopped.
Did the AIX Login Prompt display?
v Yes: Continue with the next step.
v No: Go to Problem analysis.
8. If the Resource Repair Action menu is already displayed, go to 12; otherwise, complete the following
steps:
a. Log into the operating system, either with root authority (if needed, ask the customer to enter the
password) or use the CE login.
b. Enter the diag -a command and check for missing resources. Follow any instructions that are
displayed. If a system request number (SRN) is displayed, suspect a loose card or connection. If
no instructions are displayed, no resources were detected as missing. Continue with step 9.
9. Complete the following steps:
a. Enter diag at the command prompt and press Enter.
b. Select the Diagnostics Routines option.
c. When the Diagnostic Mode Selection menu is displayed, select Problem determination.
d. When the Advanced Diagnostic Selection menu is displayed, select the All Resources option.
Alternatively, test the FRUs you exchanged and any devices that are attached to the FRUs you
exchanged by selecting the diagnostics for the individual FRU.
Did the Resource Repair Action menu (801015) display?
v Yes: Go to step 13 on page 73.
v No: Continue with the next step.
10. Did the TESTING COMPLETE, no trouble was found menu (801010) display?
v Yes: Continue with the next step.
v No: There is still a problem. Go to Problem analysis.
11. Select the Log Repair Action option, if not previously logged, in the TASK SELECTION menu to
update the AIX error log. If the repair action was reseating a cable or adapter, select the resource that
is associated with that repair action.
If the resource associated with your action is not displayed on the resource list, select sysplanar0.
Note: If the check log indicator is on, this action sets it back to the normal state. Go to step 14 on
page 73.
12. Run a test on a resource that has an entry in the AIX error log, in the system verification mode. If
the test on the resource was successful, the Resource Repair Action menu is displayed.
After you replace a FRU, select the resource for that FRU from the Resource Repair Action menu.
This action updates the AIX error log to indicate that a system-detectable FRU was replaced.
Note: If the check log indicator is on, this action sets it back to the normal state.
To select the resource for the replaced FRU, complete the following steps:
a. Select the resource that is associated with the repair action:
v If the repair action was reseating a cable or adapter, select the resource that is associated with
that repair action.
72
Power Systems: System processor modules for the 9008-22L, 9009-22A, or 9223-22H