Verifying A Repair By Using An Ibm I System Or Logical Partition - IBM Power Systems 9008-22L Manual

Power systems, system processor modules
Hide thumbs Also See for Power Systems 9008-22L:
Table of Contents

Advertisement

Did another Resource Repair Action (801015) display?
No
If the No Trouble Found menu displays, go to step 11.
Yes
Continue with the next step.
10.
The parent or child of the resource you just replaced might also require that you run the Resource
Repair Action service aid on it.
When a test is run on a resource in system verification mode, that resource has an entry in the AIX
error log. If the test on the resource was successful, the Resource Repair Action menu displays.
After replacing that FRU, you must select the resource for that FRU from the Resource Repair Action
menu. This updates the AIX error log to indicate that a system-detectable FRU has been replaced.
Note: If the check log indicator is on, this action will set it back to the normal state.
Perform the following steps:
a. From the RESOURCE REPAIR ACTION menu, select the parent or child of the resource that has
been replaced. If the repair action was reseating a cable or adapter, select the resource associated
with that repair action. If the resource associated with your action is not displayed on the
resource list, select sysplanar0.
b. Press COMMIT after you make your selections.
c. If the No Trouble Found menu is displayed, continue with the next step.
11. If you changed the service processor or network settings, as instructed in previous MAPs, restore the
settings to the value they had prior to servicing the system. If you ran stand-alone diagnostics from
CD-ROM, remove the stand-alone diagnostics CD-ROM from the system.
Did you perform service on a RAID subsystem that involvedchanging of the PCI RAID adapter
cache card or changing the configuration?
Note: This information does not apply to the PCI-X RAID adapter or cache.
No
Go to the close of call procedure.
Yes
Continue with the next step.
12. Use the Recover Options selection to resolve the RAID configuration, by completing the following
steps:
a. On the PCI SCSI Disk Array Manager display, select Recovery options.
b. If a previous configuration exists on the replacement adapter, this must be cleared. Select Clear
PCI SCSI Adapter Configuration and press F3.
c. On the Recovery Options screen, select Resolve PCI SCSI RAID Adapter Configuration.
d. On the Resolve PCI SCSI RAID Adapter Configuration screen, select Accept Configuration on
Drives.
e. On the PCI SCSI RAID Adapter selections menu, select the adapter that you changed.
f. On the next screen, press Enter.
g. When you see the Are You Sure selection menu, press Enter to continue.
h. If you see a Failed status message, verify that you selected the correct adapter, and then repeat
this procedure. When the recovery is complete, exit the operating system.
i. Go to the Closing a service call procedure.

Verifying a repair by using an IBM i system or logical partition

Use this procedure to verify a repair by using the IBM i operating system.
Procedure
1. Was the system powered off during the repair?
Yes: Continue with the next step.
64
Power Systems: System processor modules for the 9008-22L, 9009-22A, or 9223-22H