Verifying The Repair In Aix - IBM Power Systems 9008-22L Manual

Power systems, system processor modules
Hide thumbs Also See for Power Systems 9008-22L:
Table of Contents

Advertisement

v If the original problem was a failing disk drive that contained the operating system software, go to step 5.
v If the original problem was that the operating system would not load and you have another FRU to replace, go to
your FRU locations section to locate the next FRU.
v If the next FRU in the FRU list is an isolation procedure, perform the isolation procedure.
v If the original problem was that the operating system would not load and you have an isolation procedure to
complete, perform the isolation procedure.
v If the original problem was that the operating system would not load and there are no more FRUs or isolation
procedures in the FRU list, contact your next level of support.
v If you have a new problem, perform problem analysis and repair the new problem.
5. Choose from the following options:
v "Verifying the repair in AIX"
v "Verifying the repair in Linux" on page 66
v "Verifying a repair by using an IBM i system or logical partition" on page 64
v "Verifying the repair from the management console" on page 66

Verifying the repair in AIX

You can use this procedure to verify that a repair is complete using the AIX operating system.
Use this maintenance analysis procedure (MAP) to check out the server after a repair is completed.
1.
Did you replace a disk drive in the root volume group?
No
Go to step 3.
Continue with the next step.
Yes
2. Run stand-alone diagnostics either from a CD or from a Network Installation Management (NIM)
server.
Did you encounter any problems?
No
Reinstall the operating system and continue with step 5.
Yes
If the original problem still exists, replace the field-replaceable unit (FRU) or perform the
isolation procedure that is next in the FRU list. If you have reached the end of the FRU list,
contact your next level of support.
If a new problem has occurred, go to Beginning problem analysis.
3. Did you replace a FRU with the power turned on and concurrently with system operations?
No
Go to step 5.
Yes
Continue with the next step.
4. Did you use an AIX diagnostics service aid hot-swap operation to change the FRU?
No
Go to step 7 on page 63.
Yes
Go to step 6 on page 63.
Note: The AIX diagnostic service aid was used if a resource was removed by using the Hot Plug
task.
5. If any FRUs have been removed that should be reinstalled, reinstall them now:
a. If the system is not powered on, power it on now.
b. Wait until the AIX operating system login prompt is displayed or until system activity on the
operator panel or display has stopped.
c. Did you encounter any problems?
62
Power Systems: System processor modules for the 9008-22L, 9009-22A, or 9223-22H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Power systems 9009-22aPower systems 9223-22hPower system 9009-22aPower system 9008-22lPower system 9223-22h

Table of Contents