IBM 9223-22H Manual
Hide thumbs Also See for 9223-22H:

Advertisement

Quick Links

Power Systems
Adapter placement for the 5105-22E,
9008-22L, 9009-22A, 9009-22G,
9223-22H, or 9223-22S
IBM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 9223-22H and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for IBM 9223-22H

  • Page 1 Power Systems Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 2 Note Before using this information and the product it supports, read the information in “Safety notices” on page v, “Notices” on page 27, the IBM Systems Safety Notices manual, G229-9054, and the IBM Environmental Notices and User Guide, Z125–5823. ®...
  • Page 3: Table Of Contents

    Adapter placement rules and slot priorities for the system............... 6 Adapter placement rules and slot priorities for the EMX0 PCIe Gen3 I/O expansion drawer....17 Related procedures for adapter placement....................24 Finding the current system configuration in IBM i................24 Notices........................27 Accessibility features for IBM Power Systems servers................28 Privacy policy considerations ........................
  • Page 4 iv  ...
  • Page 5: Safety Notices

    Das Produkt ist nicht für den Einsatz an Bildschirmarbeitsplätzen im Sinne § 2 der Bildschirmarbeitsverordnung geeignet. Laser safety information IBM servers can use I/O cards or features that are fiber-optic based and that utilize lasers or LEDs. Laser compliance IBM servers may be installed inside or outside of an IT equipment rack.
  • Page 6 • Each rack cabinet might have more than one power cord. – For AC powered racks, be sure to disconnect all power cords in the rack cabinet when directed to disconnect power during servicing. vi  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 7 – For racks with a DC power distribution panel (PDP), turn off the circuit breaker that controls the power to the system unit(s), or disconnect the customer’s DC power source, when directed to disconnect power during servicing. • Connect all devices installed in a rack cabinet to power devices installed in the same rack cabinet.
  • Page 8 (for example, when working from a ladder). Stability hazard: • The rack may tip over causing serious personal injury. • Before extending the rack to the installation position, read the installation instructions. viii  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 9 • Do not put any load on the slide-rail mounted equipment mounted in the installation position. • Do not leave the slide-rail mounted equipment in the installation position. (L002) (L003) Safety notices  ix...
  • Page 10 There are no serviceable parts inside the device. • Use of the controls or adjustments or performance of procedures other than those specified herein might result in hazardous radiation exposure. (C026) x  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 11 Exchange only with the IBM-approved part. Recycle or discard the battery as instructed by local regulations. In the United States, IBM has a process for the collection of this battery. For information, call 1-800-426-4333. Have the IBM part number for the battery unit available when you call.
  • Page 12 Freewheeling will cause uneven cable wrapping around winch drum, damage cable, and may cause serious injury. • This TOOL must be maintained correctly for IBM Service personnel to use it. IBM shall inspect condition and verify maintenance history before operation. Personnel reserve the right not to use TOOL if inadequate.
  • Page 13 The dc-powered system employs an isolated DC return (DC-I) design. The DC battery return terminal shall not be connected to the chassis or frame ground. The dc-powered system is intended to be installed in a common bonding network (CBN) as described in GR-1089-CORE.
  • Page 14 Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 15: Adapter Placement

    Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S Find information about the placement rules and slot priorities of adapters. The following features are electromagnetic compatibility (EMC) Class B features. See the Class B Notices in the Hardware Notices section.
  • Page 16 Table 4 on page 3 lists the PCIe4 adapter slot locations and details for the 5105-22E, 9009-22G, or 9223-22S system. Figure 1. Rear view of a rack-mounted 5105-22E, 9009-22G, or 9223-22S system with PCIe4 slots location codes 2  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 17 Slot descriptions for the 9008-22L, 9009-22A, or 9223-22H The 9008-22L, 9009-22A, and 9223-22H systems provide PCIe3 and PCIe4 slots. The PCIe slots are enabled to support the PCIe3 cable adapter (FC EJ05 or EJ1R) that is used to attach the EMX0 PCIe Gen3 I/O expansion drawer.
  • Page 18 Table 5. Slot locations and descriptions for 9008-22L, 9009-22A, and 9223-22H (continued) Slot availability Description Adapter size Three slots (P1-C3, P1-C4, P1-C9) PCIe4 x16 Half-height, half-length Two slots (P1-C2, P1-C8) PCIe4 x8 with x16 connector Half-height, half-length Two PCIe3 switches in the system backplane provide PCIe3 buses from the system processor modules that provide connectivity to the following features: •...
  • Page 19 Figure 2. Rear view of a rack-mounted 9008-22L, 9009-22A, or 9223-22H system with PCIe slots location codes Table 7. Slot locations and descriptions for the 9008-22L, 9009-22A, or 9223-22H system Location code Description Processor Adapter size Slot capabilities Slot module...
  • Page 20: Adapter Placement Rules And Slot Priorities For The System

    Table 7. Slot locations and descriptions for the 9008-22L, 9009-22A, or 9223-22H system (continued) Location code Description Processor Adapter size Slot capabilities Slot module availability CAPI SR-IOV 32-bit I/O adapter dynamic direct enlarged memory capacity access (DMA) enablement order 6 1 High-performance slot that is directly connected to the processor module.
  • Page 21 11, 8, 9, 7, 10, 12, 6, 11, 7, 12, 6, 2, 5, 10, & RoCE SR/Cu adapter 8, 4, 3, 9 (FC EC2R and EC2S; CCIN 58FA); Adapter part number: 01FT759 Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  7...
  • Page 22 2, 8, 3, 9, 4, 6, 12, 5, Memory 1.6 TB SSD 10, 7 NVMe adapter (FC EC5A, EC5B, EC5G, EC6U, and EC6V; CCIN 58FC); Adapter part number: 01DH570 8  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 23 CCIN 594C); Adapter part number: 02DE964 EJ05 2 PCIe3 cable adapter for 9/10, 4/5 the EMX0 PCIe Gen3 I/O expansion drawer (FC EJ05; CCIN 2B1C); Adapter part number: 00RR809 Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  9...
  • Page 24 11, 12, 6, 7, 10, 5, 8, 11, 12, 6, 7, 5, 10, 8, GbE BaseT RJ45 adapter 2, 9, 4, 3 (FC EL3Z or EN0X; CCIN 2CC4); Adapter part number: 00E2714 10  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 25 2 The adapter is not supported on the 5105-22E system. Adapter placement rules for 9008-22L, 9009-22A, or 9223-22H Use this information while selecting slots for installing adapters in the 9008-22L, 9009-22A, or 9223-22H system. 1. The slot P1-C11 must be used to install the local area network (LAN) adapter feature codes (FCs). Any other adapter feature is not supported in this slot.
  • Page 26 Note: In the following table, the slot priority numbers 2 - 4 correspond to slot locations P1-C2 through P1-C4. And slot priority numbers 6 - 12 correspond to slot locations P1-C6 through P1-C12. Table 9. Adapter slot priorities and maximum adapters supported in the 9008-22L, 9009-22A, or 9223-22H system Feature...
  • Page 27 Table 9. Adapter slot priorities and maximum adapters supported in the 9008-22L, 9009-22A, or 9223-22H system (continued) Feature Description 9009-22A or 9223-22H 9009-22A or 9223-22H 9008-22L 9008-22L code (one processor) (two processors) (one processor) (two processors) Slot Maximum Slot Maximum...
  • Page 28 Table 9. Adapter slot priorities and maximum adapters supported in the 9008-22L, 9009-22A, or 9223-22H system (continued) Feature Description 9009-22A or 9223-22H 9009-22A or 9223-22H 9008-22L 9008-22L code (one processor) (two processors) (one processor) (two processors) Slot Maximum Slot Maximum...
  • Page 29 Table 9. Adapter slot priorities and maximum adapters supported in the 9008-22L, 9009-22A, or 9223-22H system (continued) Feature Description 9009-22A or 9223-22H 9009-22A or 9223-22H 9008-22L 9008-22L code (one processor) (two processors) (one processor) (two processors) Slot Maximum Slot Maximum...
  • Page 30 Table 9. Adapter slot priorities and maximum adapters supported in the 9008-22L, 9009-22A, or 9223-22H system (continued) Feature Description 9009-22A or 9223-22H 9009-22A or 9223-22H 9008-22L 9008-22L code (one processor) (two processors) (one processor) (two processors) Slot Maximum Slot Maximum...
  • Page 31: Adapter Placement Rules And Slot Priorities For The Emx0 Pcie Gen3 I/O Expansion Drawer

    The right I/O module bay is configured with the second PCIe3 6-slot fanout module slot location codes P2-C1 through P2-C6. Figure 3. Rear view of a EMX0 PCIe3 expansion drawer with PCIe slot location codes Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  17...
  • Page 32 • All other I/O adapter slots are allocated Dynamic DMA Window (DDW) capability based on installed platform memory. DDW capability is calculated assuming 4K I/O mappings: – For systems with less than 64 GB of memory, slots are allocated no DDW capability. 18  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 33 577D); Adapter part number: C3, P1-C5, P2-C5, 10N9824 P1-C6, P2-C6 5785 4-port Async EIA-232 PCIe P1-C6, P2-C6 1X adapter (FC 5277 and 5785; CCIN 57D2); Adapter part number: 46K6734 Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  19...
  • Page 34 EJ0J PCIe3 SAS RAID quad-port P1-C1, P2-C1, P1- 6 Gb adapter (FC EJ0J and C4, P2-C4, P1-C3, EL59); CCIN 57B4); Adapter part P2-C3, P1-C6, P2-C6 number: 00FX846 20  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 35 RoCE SR adapter (FC EC2M, C4, P2-C4, P1-C2, EC2N, and EL54; CCIN 57BE); P2-C2, P1-C3, P2- Adapter part number: full-height C3, P1-C5, P2-C5, tailstock: 00RX875, low-profile P1-C6, P2-C6 tailstock: 00RX872 Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  21...
  • Page 36 SR+RJ45 adapter (FC EN0S, C4, P2-C4, P1-C2, FC EN0T, FC EN0U, and FC P2-C2, P1-C3, P2- EN0V; CCIN 2CC3); Adapter part C3, P1-C5, P2-C5, number: 00E2715 P1-C6, P2-C6 22  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 37 PCIe3 x8 4-port Fibre Channel P1-C2, P2-C2, P1- (16 Gb/s); (FC EN1E and C5, P2-C5, P1-C3, EN1F; CCIN 579A); Adapter part P2-C3, P1-C6, P2- number: 02JD586 C6, P1-C1, P2-C1, P1-C4, P2-C4 Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  23...
  • Page 38: Related Procedures For Adapter Placement

    About this task To find the current system configuration, start an IBM i session and sign on. If you have more than one system, start a session on the system that is being upgraded and for which you have service tools authority.
  • Page 39 Type 9 for the System Expansion Unit field and press Enter. b. Repeat steps 7-11 for each expansion unit. c. Select an available slot in the expansion unit. Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S  25...
  • Page 40 26  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 41: Notices

    Consult your local IBM representative for information on the products and services currently available in your area. Any reference to an IBM product, program, or service is not intended to state or imply that only that IBM product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any IBM intellectual property right may be used instead.
  • Page 42: Accessibility Features For Ibm Power Systems Servers

    This product uses standard navigation keys. Interface information The IBM Power Systems servers user interfaces do not have content that flashes 2 - 55 times per second. The IBM Power Systems servers web user interface relies on cascading style sheets to render content properly and to provide a usable experience.
  • Page 43: Privacy Policy Considerations

    Contact the vendor for accessibility information about its products. Related accessibility information In addition to standard IBM help desk and support websites, IBM has a TTY telephone service for use by deaf or hard of hearing customers to access sales and support services:...
  • Page 44 Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 45 Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 / EN 55032 Klasse A. Japan Electronics and Information Technology Industries Association (JEITA) Notice This statement applies to products less than or equal to 20 A per phase. This statement applies to products greater than 20 A, single phase.
  • Page 46 Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits. Proper cables and connectors are available from IBM-authorized dealers. IBM is not responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modifications to this equipment.
  • Page 47: Class B Notices

    Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben. Des Weiteren dürfen auch nur von der IBM empfohlene Kabel angeschlossen werden. IBM übernimmt keine Verantwortung für die Einhaltung der Schutzanforderungen, wenn das Produkt ohne Zustimmung von IBM verändert bzw.
  • Page 48 This statement applies to products greater than 20 A, single phase. This statement applies to products greater than 20 A per phase, three-phase. Japan Voluntary Control Council for Interference (VCCI) Notice 34  Power Systems: Adapter placement for the 5105-22E, 9008-22L, 9009-22A, 9009-22G, 9223-22H, or 9223-22S...
  • Page 49: Terms And Conditions

    Permissions for the use of these publications are granted subject to the following terms and conditions. Applicability: These terms and conditions are in addition to any terms of use for the IBM website. Personal Use: You may reproduce these publications for your personal, noncommercial use provided that all proprietary notices are preserved.
  • Page 50 IBM reserves the right to withdraw the permissions granted herein whenever, in its discretion, the use of the publications is detrimental to its interest or, as determined by IBM, the above instructions are not being properly followed. You may not download, export or re-export this information except in full compliance with all applicable laws and regulations, including all United States export laws and regulations.
  • Page 52 IBM®...

This manual is also suitable for:

9008-22l9009-22a9009-22g5105-22e9223-22s

Table of Contents