System Error Messages - Bomar Individual Automatic Series Operating Instructions Manual

Hide thumbs Also See for Individual Automatic Series:
Table of Contents

Advertisement

3.6.
42
Continue in automatic cycle
»
The process interrupted in this way can be continued – if the operator returns to the
Automatic mode, the following menu is displayed. Press the function button Continue to
continue with the automatic cycle from the position of interruption. Select item Stop to finish
the automatic process; the operator may start the new process with new values.

System error messages

Error message
Description
Safety circuit
The safety circuit is not switched on; the machine
cannot be used.
Press the safety circuit button on the control
panel (pos. 10)
Machine reference
The machine cannot start without referencing –
see chapter Referencing of the machine.
Proceed according to directions in message –turn
the key to position 0 and select Machine
referencing in the menu.
Saw band
The system monitoring saw band stretching level
detected insufficient stretching.
Stretch the band to recommended level.
Manual version:
Manual rev.:
1.10 / Jan. 2011