3.3.2.
34
Pos.
Main vice opening time – vice opening time. The vice opens only for this period of
1.
time, does not opens fully to save the time.
Feeding vice opening time – Guarding time of the hydraulics to open the feeding
2.
vice.
Multiple time factor for vice clamping – Check time for vice clamping. The time
factors correspond with multiple check time on the pressure switch.
3.
1 – is detected as clamped if during the certain time interval (100% of the time interval)
no change of the pressure is detected on the pressure switch.
e.g. 1,2 – the vice will be detected as clamped if no pressure change will be detected
on the pressure switch for 100% × 1,2 time interval (i.e. for 20% longer time period).
Feeding vice prior to cutting – Setting of the feeding vice prior to cutting – open /
4.
closed.
Operation time of the remover after cutting – Time of operation of the remover after
5.
the cut has been finished.
Note: Chip remover is auxiliary accessory.
Offcut correction – width of the saw band, important value for calculation of the
6.
lengths in automatic mode.
7.
Correction of multiple feeding – correction for correct operation of the feeder.

Service parameters 2

1
2
3
4
Pos.
1.
Feeder travel length – parameter of the maximum feeder length for multiple feeds.
2.
Feeder speed – maximum speed of feeder
Feeder acceleration – value of the feeder acceleration. The parameter is suitable for
3.
feeding heavy and unstable material (due to base shape and dimensions). These values
are used only for movement with loaded feeder.
Feeder deceleration – value of the feeder deceleration (breaking). The parameter is
4.
suitable for feeding heavy and unstable material (due to base shape and dimensions).
These values are used only for movement with loaded feeder.
Selection of the units for length in control system –
5.
metric (mm)
imperial (inches)
Function
Function
Manual version:
Manual rev.:
5
6
7
8
1.10 / Jan. 2011