Working Cycle Interruption; Error Messages; Selection Of Saw Band Speed - Bomar Practix Automatic Series Operating Instructions Manual

Table of Contents

Advertisement

3.4.
3.5.
3.6.
38

Working cycle interruption

When TOTAL STOP is pressed, saw band operation is stopped.
Press STOP button (pos. G) to stop the current cycle.
Press TOTAL STOP button in emergency.
Position of safety button TOTAL STOP and STOP button:

Error messages

Safety circuit not switched on
Press the safety circuit button to start the control circuits of
the control system.
Control circuits start is signalized by light in button.
Start the safety circuit using designated
button on the control panel.
Motor overload
Motor is disconnected
End switch of belt tensioning detected problem
Check saw belt tension, or re-tension it, see Tensioning and
check of saw band.
TOTAL STOP safety button pressed
Feeding vice clamp error
Check if the material is correctly clamped (see chapter
Clamping of material to vice)
Main vice clamp error
Check if the material is correctly clamped (see chapter
Clamping of material to vice)
Wrong length set
Max. length of cut piece is 3270 mm

Selection of saw band speed

Selector in position 1
-1
speed 35 m.min
˙Safety button˙
˙
is off
˙
˙Fault motor
˙
˙protector
˙
Blade tension ˙
˙fault
˙
˙
Total Stop ˙
˙
pressed
˙
˙ Stop cycle
˙
Main vice fault
˙ Stop cycle
˙
Feed vice fault
˙
Error max. ˙
length 3270 mm
Selector in position 2
-1
speed 72 m.min
Manual version:
Manual rev.:
1.00/ May. 2010