High Voltage Wire Gauge Requirements; Instruction 11: Connect Battery Cables To Battery - Nice 7251 Installation And Programming Manual

Vehicular pad or post-mount slide gate operator with 1050 control board
Hide thumbs Also See for 7251:
Table of Contents

Advertisement

Power should not be applied to the control board until after the photo eyes have been installed
and wired to the control board. Power is applied in INSTRUCTIONS 12, 13, and/or 14.

11.1 HIGH VOLTAGE WIRE GAUGE REQUIREMENTS

Use Table below to determine high voltage wire size requirements. Distance shown in the chart is measured
from the operator to the power source. If power wiring is greater than the maximum distance shown, a service
feeder is recommended. When large gauge wire is used, a separate junction box must be installed for the
operator connection.
Wire table is based on stranded copper wire. Wire run calculations are based on a 110 VAC power source with
a 3% voltage drop on the power line, plus an additional 10% reduction in distance to allow for other electrical
losses in the system.
110V/AWG GAUGE
MAX RUN
11
CONNECT BATTERY CABLES TO BATTERY
1. Locate the two battery leads (red & black with with battery lugs) inside unit (IMAGE 11-1).
2. Attach lugs of the battery cable to the battery terminals; black to negative (-) and red to positive (+)
terminals.
BATTERY
NOTE: LED below the terminal will glow red if battery is mis-wired.
www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com
28
7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
TABLE 11-1: MAXIMUM RUN PER WIRE GAUGE
14
12
180 FT
280 FT
(54.8m)
(85.3m)
IMAGE 11-1: BATTERY CABLES
IMPORTANT!
10
8
460 FT
700 FT
(140m)
(213.3m)
6
4
1150 FT
1800 FT
(350.5m)
(548.6m)