Nice 7251 Installation And Programming Manual page 65

Vehicular pad or post-mount slide gate operator with 1050 control board
Hide thumbs Also See for 7251:
Table of Contents

Advertisement

EDGE INPUT (28-29):
The EDGE input may be configured as a monitored ANALOG input,
or DIGITAL (NC or NO) input.
The EDGE sensor input is intended for ANSI/UL 325 listed gate
edge sensors to protect against entrapment and hazardous pinch
points along the moving edge of the closing gate.
Additional options are available to declare if the edge is protecting
the open or close direction, and the input must measure 8.2K - 10K
Ohms.
When the input is activated it stops the gate regardless of direction
of travel, momentarily reverses it then stops.
PIN 28 = EDGE
PIN 29 = GND
EXIT INPUT (30-31):
The EXIT sensor input is provided to activate to open the gate, or re-open a closing gate, upon sensing an
exiting vehicle.
This is a dry contact input for a vehicle exit sensor.
Shorting the EXIT input to GND opens gate from the closed position and holds gate open with maintained
input or reverses gate if closing.
PIN 30 = EXIT
PIN 31 = GND
FIRE INPUT (32-33):
Dry contact input for a fire department control switch.
Shorting the Fire input (32) to GND opens the gate and holds the gate open
until control switch is deactivated.
Auto-close is disabled when this input is activated. Also clears hard shutdown.
PIN 32 = FIRE
PIN 33 = GND
www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com
7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
EXIT DEVICE
EDGE SENSOR AND
EXIT DEVICE WIRING
(EXAMPLE)
FIRE DEPT. INPUT
WIRING (EXAMPLE)
65