7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
10
(min-max
OK
sensitivity)
:5
1
10
(min-max
OK
sensitivity)
:5
0
EXIT
OK
100%
OK
:100
20%
100%
OK
:100
20%
100%
OK
:50
20%
100%
OK
:50
20%
10
(Low
OK
to High)
:10
3
10
OK
:5
1
EXIT
OK
FORCE BUTTON MENU:
Amount of force needed to cause the gate to stop
and reverse when hitting an obstacle.
• STATIC: Set sensitivity to constant force on a
scale of 1 to 10 (1 being the most sensitive).
• DYNAMIC: Set sensitivity of sudden impact
force to the moving gate on a scale of 1 to 10
(1 being most sensitive). 0 = OFF.
• EXIT: Exits the FORCE menu.
SPEED BUTTON MENU:
Sets the speed of the gate under various conditions.
• MAX: Sets limit of max allowed gate speed on scale of 20%
to 100% (20% is lowest setting). It is recommended to set
to default of 100.
• STANDARD: Sets limit of the gate speed during normal
movement (not soft start/stop) on scale of 20% to 100%
(20% being the lowest setting). It is recommended to set to
default of 100.
• LOW: Sets limit of the gate speed while in LEARNING mode
and when moving in SLOW, on scale of 20% to 100% (20%
being the lowest setting). Recommended not to be set lower
than 50. Default setting depends upon learning parameters
• SLOWDOWN: Set gate speed when approaching the open
or close limits on scale of 20% to 100% (20% being the lowest
setting). Recommended not to set lower than 50% for slide
gates. The lower this setting the less power the operator
will have when approaching the limit. Setting too low could
cause a stall condition prior to open/close limit.
• ACCELERATION: Adjusts the rate of acceleration/
deceleration when the motor starts and stops moving:
» MAX:
Sets the limit of gate acceleration and
when reversing the gate after an obstacle has been
detected by the UL/Edge or current sense feature (Force).
Settings from 3 to 10, with 10 being the highest rate of
gate acceleration.
» STANDARD:
Sets the limit of the gate acceleration and
deceleration in normal operation. Settings from 1 to 10,
with 10 being the highest rate of gate acceleration. * *TO
PREVENT DAMAGE TO THE GATE OR THE CONTROLLER
USE LOWER ACCELERATION SETTINGS FOR HEAVIER
GATES.
» ESC:
Exit the SPEED / ACCELERATION menus.
deceleration
45