LAMP (12-13):
Provides fused power (1.85A max) to drive a flashing warning lamp to indicate gate operation.
This output is active when the gate is operating (Opening and Closing).
Lamp Delay sets the amount of time the lamp accessory output is activated prior to gate movement. Settings
from 0 to 5 seconds with a step of 0.5 seconds.
PIN 12 = LAMP
PIN 13 = GND (Ground)
ALARM (14-15):
Provides fused power (0.5A @ 12VDC) to drive an alarm siren to signal the occurrence of a hard shutdown,
caused by 2 consecutive entrapment events (signals).
This alarm output is reset by pressing the "Reset Hard Shutdown" button on the front panel or activating the
"FIRE" input.
PIN 14 = ALARM
PIN 15 = GND (Ground)
24VDC POWER OUTPUT (20-21):
This power output is located along the lower strip of input connectors at pins 20 and 21.
Pin 20 outputs a +24 Volts DC current, which is regulated and turns off when the control board goes into sleep
mode (power saving mode).
This output may be used to power accessories that are required to power-down when board enters power
saving mode. This is primarily beneficial for solar powered configurations where it is desirable to reduce
power consumption.
PIN 20 = +24VDC Regulated
PIN 21 = GND (Ground)