15.1 OUTPUT CONNECTORS
OUT 1 / OUT 2 (1-6):
Individual, isolated relays provide dry contacts for switching accessories based on programming of the "Auxiliary
IO" function. These outputs are programmed in the "FUNCTION / Auxiliary I/O" menu.
OUT 1
PIN 1 = N.C. (Normally Closed)
PIN 2 = Com (Common)
PIN 3 = N.O. (Normally Open)
MAGNETIC LOCK (7-11):
•
Provides fused power (1.85A max) and isolated relay dry contacts for electrically powered and maintained
magnetic locks.
•
This connection is used to install the magnetic lock. Consult lock manual for specifics on installation and
wiring.
•
The output time for magnetic lock activation/deactivation may be adjusted from 0 to 5 seconds.
• When the control board is in standby mode, power is still present at terminals 10 and 11. If standby mode is
used (especially in a solar application) and a magnetic lock is not used, terminals 10 and 11 may be used to
provide power to other accessories.
PIN 7 = N.C. (Normally Closed)
PIN 8 = Com (Common)
PIN 9 = N.O. (Normally Open)
PIN 10 = GND (Ground)
*
PIN 11 = V+
POWER OUT
*
NOTES:
The output voltage of terminal 11 is the same as the highest incoming
voltage (on battery OR Main DC Power) to the control board.
EXAMPLES:
• If you are using a 12VDC battery to power the control board connected
to the Battery input, and the voltage of the battery is 13.5VDC - terminal
11 will have a 13.5VDC output.
• If you are using a power supply input of 32VDC to the control board
connected to the Main DC Power input - terminal 11 will have a 32VDC
output.
• If you are using a power supply connected to Main DC Power (at 32VDC)
and also using a battery connected to the Battery input (at 13.5VDC)
- terminal 11 will have an output of 32VDC.
www.ApolloGateOpeners.com | (800) 878-7829 | Sales@ApolloGateOpeners.com
62
7251 / 7351 Slide Gate Operator
INSTALLATION AND PROGRAMMING MANUAL
OUT 2
PIN 4 = N.C. (Normally Closed)
PIN 5 = Com (Common)
PIN 6 = N.O. (Normally Open)
1 1
1 0
9
8
7
MAGNETIC LOCK
WIRING (EXAMPLE)
AUX. POWER OUT
WIRING (EXAMPLE)