Step #6 - Install Lock
1. Feed wires into the lock body hole from outside of door (Fig.6A).
2. Slide lock body into cross-bore hole from outside (locked side)
of the door (Fig. 6B).
3. Lock body must engage both the latch unit prongs
and tail piece (Fig. 6C Detail).
IMPORTANT:
• Latchbolt screws remain partially tightened.
• Door must remain open during installation. Use door stop.
• Lock body must be centered in the door.
Inside
Step #7 – Secure the Lock to the Door
1A. For wood door: Feed wires up through the routed
channel (Fig. 7A).
1B. For metal door: Feed wires and connector through
inside of door (not shown).
2. Slide inside rose assembly and spacer bushing
over lock body and secure with (2) #10-32x1-1/4" through-bolts.
3. Secure with (2) additional #6 x 3/4" self-tapping screws.
Note: Refer to preceding page to remove outside lever.
4. Tighten latch screws securely.
14
A7763B
Outside
DPS
2
Fig..6B..Detail
Latchbolt Screws
(Partially Tightened)